首页> 外文期刊>Journal of materials in civil engineering >Steady-State Chloride Diffusion Coefficient and Chloride Migration Coefficient of Cracks in Concrete
【24h】

Steady-State Chloride Diffusion Coefficient and Chloride Migration Coefficient of Cracks in Concrete

机译:混凝土裂缝的稳态氯化物扩散系数和氯化物迁移系数

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Prediction of chloride ingress is very important for the durability of reinforced concrete structures in chloride-laden environments, especially for concrete with cracks. It is expected that the chloride diffusion coefficient of a crack is much higher than that of the uncracked part in concrete. A single crack in concrete can be a shortcut for chloride ions to pass through. Research on chloride diffusion/migration through cracks in concrete is limited. Therefore, in this paper steady-state chloride diffusion and migration coefficients of cracks in concrete were measured and calculated and the relationship between the two coefficient types was analyzed theoretically and compared with experimental data. The results show that the ratio between the two sets of diffusion/migration coefficients can be related to the ratio between the specimen length and crack length. The measured crack length depends on the resolution of the sampling by microscopy. The optimum unit sampling length for the crack length measurement was found be close to the value of crack width.
机译:氯化物进入的预测对于在充满氯化物的环境中钢筋混凝土结构的耐久性非常重要,特别是对于有裂缝的混凝土。预期裂缝中的氯离子扩散系数比混凝土中未破裂部分的氯离子扩散系数高得多。混凝土中的单个裂缝可能是氯离子通过的捷径。氯离子通过混凝土裂缝扩散/迁移的研究是有限的。因此,本文测量并计算了稳态氯化物在混凝土中的扩散和裂缝的迁移系数,并对两种系数类型之间的关系进行了理论分析,并与实验数据进行了比较。结果表明,两组扩散/迁移系数之间的比率与试样长度与裂纹长度之间的比率有关。测得的裂纹长度取决于通过显微镜检查的采样分辨率。发现用于裂纹长度测量的最佳单位采样长度接近于裂纹宽度的值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号