首页> 外文期刊>Journal of Hazardous Materials >Evaluation of passenger health risk assessment of sustainable indoor air quality monitoring in metro systems based on a non-Gaussian dynamic sensor validation method
【24h】

Evaluation of passenger health risk assessment of sustainable indoor air quality monitoring in metro systems based on a non-Gaussian dynamic sensor validation method

机译:基于非高斯动态传感器验证方法的地铁系统可持续室内空气质量监测乘客健康风险评估

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Sensor faults in metro systems provide incorrect information to indoor air quality (IAQ) ventilation systems, resulting in the miss-operation of ventilation systems and adverse effects on passenger health. In this study, a new sensor validation method is proposed to (1) detect, identify and repair sensor faults and (2) evaluate the influence of sensor reliability on passenger health risk. To address the dynamic non-Gaussianity problem of IAQ data, dynamic independent component analysis (DICA) is used. To detect and identify sensor faults, the DICA-based squared prediction error and sensor validity index are used, respectively. To restore the faults to normal measurements, a DICA-based iterative reconstruction algorithm is proposed. The comprehensive indoor air-quality index (CIAI) that evaluates the influence of the current IAQ on passenger health is then compared using the faulty and reconstructed IAQdata sets. Experimental results from a metro station showed that the DICA-based method can produce an improved IAQ level in the metro station and reduce passenger health risk since it more accurately validates sensor faults than do conventional methods.
机译:地铁系统中的传感器故障为室内空气质量(IAQ)通风系统提供了不正确的信息,从而导致通风系统误操作并对乘客健康产生不利影响。在这项研究中,提出了一种新的传感器验证方法,以(1)检测,识别和修复传感器故障,以及(2)评估传感器可靠性对乘客健康风险的影响。为了解决IAQ数据的动态非高斯性问题,使用了动态独立分量分析(DICA)。为了检测和识别传感器故障,分别使用了基于DICA的平方预测误差和传感器有效性指标。为了将故障恢复到正常状态,提出了一种基于DICA的迭代重建算法。然后,使用故障的和重建的IAQ数据集比较评估当前IAQ对乘客健康影响的综合室内空气质量指数(CIAI)。地铁站的实验结果表明,基于DICA的方法可以比常规方法更准确地验证传感器故障,因此可以提高地铁站的IAQ水平并降低乘客的健康风险。

著录项

  • 来源
    《Journal of Hazardous Materials》 |2014年第15期|124-133|共10页
  • 作者单位

    Department of Environmental Science and Engineering, Center for Environmental Studies, Kyung Hee University, Yongin 446-701, Republic of Korea;

    Department of Environmental Science and Engineering, Center for Environmental Studies, Kyung Hee University, Yongin 446-701, Republic of Korea;

    Department of Architectural Engineering, Center for Sustainable Healthy Buildings, Kyung Hee University, Yongin 446-701, Republic of Korea;

    Department of Environmental Science and Engineering, Center for Environmental Studies, Kyung Hee University, Yongin 446-701, Republic of Korea;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Sensor fault validation; Dynamic independent component analysis (DICA); Indoor air quality (IAQ); Health risk assessment; Metro systems;

    机译:传感器故障验证;动态独立成分分析(DICA);室内空气质量(IAQ);健康风险评估;地铁系统;