首页> 外文期刊>Journal of Clinical Monitoring and Computing >Effect of wearing an N95 respirator on infrared tympanic membrane temperature measurements
【24h】

Effect of wearing an N95 respirator on infrared tympanic membrane temperature measurements

机译:佩戴N95防毒面具对红外鼓膜温度测量的影响

获取原文
获取原文并翻译 | 示例
           

摘要

To determine the impact of wearing an N95 filtering facepiece respirator (N95 FFR) on tympanic temperature measurements. TMT measurements, with and without wearing an N95 filtering facepiece respirator (N95 FFR) were obtained at the onset and termination of 1 h of treadmill exercise in 21 subjects, and at staggered time intervals (0, 20, 40, 60 min) during combined sedentary activity and exercise of another 46 subjects, to determine any effect on TMT. A total of 877 TMT measurements were obtained that demonstrated a mean TMT increase of 0.05 °C in the first study group (p = 0.04) and a 0.19 °C decrease in the second study group (p < 0.001) with the wearing of an N95 FFR, both of which were lower than controls. Wearing an N95 FFR for 1 h, at different levels of activity, results in significantly lower TMT values than not wearing an N95 FFR, but the magnitude of the changes would likely have minimal clinical significance.
机译:确定佩戴N95过滤式面罩呼吸器(N95 FFR)对鼓膜温度测量的影响。在21名受试者的跑步机运动开始1小时和结束1h的情况下,在有和没有佩戴N95过滤式面罩呼吸器(N95 FFR)的情况下进行TMT测量,并在组合过程中以交错的时间间隔(0、20、40、60分钟)久坐活动和运动的另外46位受试者,以确定对TMT的影响。总共进行了877次TMT测量,结果表明在佩戴N95的情况下,第一个研究组的平均TMT增加了0.05°C(p = 0.04),第二个研究组的平均TMT降低了0.19°C(p <0.001) FFR,两者均低于对照。与不佩戴N95 FFR相比,在不同活动水平下佩戴N95 FFR 1小时会导致TMT值明显降低,但变化幅度可能对临床意义不大。

著录项

  • 来源
    《Journal of Clinical Monitoring and Computing》 |2015年第6期|691-695|共5页
  • 作者单位

    Technology Research Branch of the National Personal Protective Technology Laboratory National Institute for Occupational Safety and Health Centers for Disease Control and Prevention">(1);

    Technology Research Branch of the National Personal Protective Technology Laboratory National Institute for Occupational Safety and Health Centers for Disease Control and Prevention">(1);

    Technology Research Branch of the National Personal Protective Technology Laboratory National Institute for Occupational Safety and Health Centers for Disease Control and Prevention">(1);

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    N95 filtering facepiece respirators; Tympanic membrane temperature;

    机译:N95过滤式面罩呼吸器;鼓膜温度;