首页> 外文期刊>International journal of environmental analytical chemistry >On-line separation and preconcentration of trace cadmium in environmental water samples by micro column filled with modified nanometer Si-HAP prior to FAAS determination
【24h】

On-line separation and preconcentration of trace cadmium in environmental water samples by micro column filled with modified nanometer Si-HAP prior to FAAS determination

机译:FAAS测定前,通过填充改性纳米Si-HAP的微柱在线分离和富集环境水样中的痕量镉

获取原文
获取原文并翻译 | 示例
           

摘要

A novel method of on-line solid phase extraction (SPE) preconcentration has been established for the determination of cadmium in environmental water samples by flame atomic absorption spectrometry (FAAS). The method is based on the on-line retention of cadmium on a micro column of nanometer Silicon Hydroxyapatite (Si-HAP) modified with l-phenyl-3-methyl-4-bonzoil-5-pyrazone (PMBP) and subsequent elution with 1.0 M thiourea and determination by FAAS. The effect of various parameters that could affect the performance of the system was investigated. The enrichment factor (EF) for cadmium (II) was 250. The limit of detection (LOD) obtained under optimum conditions was 0.28 μg L~(-1) and the relative standard deviation (RSD) for seven replicates at 100 μg L~(-1) Cd~(2+) concentration level was 1.4%. The method was applied to water samples and standard reference materials. The accuracy was assessed through recovery experiments and comparing the results with the accepted values of standard reference material.
机译:建立了一种在线固相萃取(SPE)预富集的新方法,用于通过火焰原子吸收光谱法(FAAS)测定环境水样品中的镉。该方法基于镉在用l-苯基-3-甲基-4-bonzoil-5-pyrazone(PMBP)改性的纳米羟基羟基磷灰石(Si-HAP)的微柱上的在线保留,然后用1.0洗脱硫脲和FAAS测定。研究了可能影响系统性能的各种参数的影响。镉(II)的富集因子(EF)为250。在最佳条件下获得的检出限(LOD)为0.28μgL〜(-1),在100μgL〜下进行7次重复测定的相对标准偏差(RSD) (-1)Cd〜(2+)浓度为1.4%。该方法适用于水样和标准参考物质。通过回收率实验评估准确性,并将结果与​​标准参考物质的可接受值进行比较。

著录项

  • 来源
  • 作者单位

    Key Laboratory of Environmentally Friendly Chemistry and Applications of Ministry of Education, Xiangtan University, Xiangtan, Hunan 411105, P.R. China;

    Key Laboratory of Environmentally Friendly Chemistry and Applications of Ministry of Education, Xiangtan University, Xiangtan, Hunan 411105, P.R. China;

    Key Laboratory of Environmentally Friendly Chemistry and Applications of Ministry of Education, Xiangtan University, Xiangtan, Hunan 411105, P.R. China;

    Key Laboratory of Environmentally Friendly Chemistry and Applications of Ministry of Education, Xiangtan University, Xiangtan, Hunan 411105, P.R. China;

    Key Laboratory of Biogeology and Environmental Geology of Chinese Ministry of Education & Sino-Hungarian Joint Laboratory of Environmental Science and Health, China University of Geosciences, 430074 Wuhan, P.R. China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    on-line preconcentration; modified nanometer material; micro column analysis; cadmium; FAAS;

    机译:在线预浓缩;改性纳米材料;微柱分析;镉;联邦航空局;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号