International Comparison of Charpy Impact Test

机译:夏比冲击试验的国际比较

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

An international comparison of Charpy impact test was made. The organization which participated in the comparison were NIST(USA), LNE(France), IRMM(European Commision) and NRLM(Ja- pan). This atudy was the first horizontal comparison between these metrological laboratories. The Japanese specimens at three different energy levels were tested according to JIS 7722(1990) by each laboratory. The results showed that the CV values ranged from 0.02 to 0.04, and most of absorbed en- ergies were within ±2J or the ±5 limit of the grand average. IN addition, other verification speci- mens provided by the participating laboratories were tested by the NRLM standard impact machine. The results for the test were all within ±2J or the ±5 limit except for NIST specimens with the 2 mm striker. The comparison procedures and the experimental results in NRLM are presented.
机译:对夏比冲击试验进行了国际比较。参加比较的组织是NIST(美国),LNE(法国),IRMM(欧洲委员会)和NRLM(日本)。该测验是这些计量实验室之间的首次水平比较。每个实验室根据JIS 7722(1990)对三种不同能级的日本样品进行了测试。结果表明,CV值在0.02至0.04的范围内,并且大多数吸收能量在±2J或总体平均值的±5范围内。此外,由参与实验室提供的其他验证标本已通过NRLM标准冲击机进行了测试。除带有2 mm撞针的NIST样品外,测试结果均在±2J或±5范围内。介绍了NRLM中的比较程序和实验结果。