In order to determine the limiting velocity resolution that can benachieved using ultrasound, and to provide a model which can bengeneralized for the analysis of disturbed flow, a theoretical andnexperimental evaluation of the statistics of the received signal fromnlaminar flow following the transmission of a train of short pulses isnpresented. The authors derive the autocorrelation function and determinenthe length of the correlated signal for various flow rates, comparingnexperimental measurements to theoretical predictions. High resolutionnexperimental RF M-mode images are used to verify the theoretical model.nUsing a fluid with a density, viscosity, volume concentration, particlensize, and speed of sound which is similar to that of blood, the authorsnshow that the signal remains correlated for a long interval under manynconditions of clinical interest. Including a comparison withnexperimental data, the effect of the lateral transit time through thensample volume and the axial velocity spread within the sample volume onnthe correlation of the received signal is evaluated. When a significantnrange of velocity components is present within the sample volume, thisnrange is the limiting factor in the length of the correlated signalninterval. Therefore, the use of a wideband signal, which reduces thensample volume size, produces a returned signal that may be correlatednfor a larger number of pulses, or for a longer time
机译:为了确定可以使用超声波获得的极限速度分辨率,并提供可以被一般化用于分析扰动流的模型,在短程传输之后,对来自层流的接收信号的统计数据进行理论和实验评估脉冲表示。作者得出自相关函数,并确定各种流量下相关信号的长度,将实验测量值与理论预测值进行比较。高分辨率n实验RF M模式图像用于验证理论模型。作者使用密度,粘度,体积浓度,粒径和声速与血液相似的流体,作者n表示信号对于在许多具有临床意义的条件下间隔较长。包括与实验数据的比较,评估了通过样品体积的横向移动时间以及样品体积内轴向速度扩展对接收信号相关性的影响。当样本体积内存在很大范围的速度分量时,该范围是相关信号间隔长度的限制因素。因此,使用宽带信号会减小样本量,从而产生返回的信号,该信号可能与较大数量的脉冲或较长时间相关

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号