A new formulation for obtaining the absolute backscatterncoefficient from pulse-echo measurements is presented. Using thisnformulation, performing the diffraction correction and systemncalibration is straightforward. The diffraction correction function fornthe measurement of backscatter coefficient and the acoustic couplingnfunction for a pulse-echo system are defined. Details of these functionsnfor two very useful cases are presented: a flat disk transducer and anspherically focused transducer. Approximations of these functions arenalso provided. For a flat disk transducer, the final formulation appearsnas a modification to the established Sigelmann-Reid formulation. For anfocused transducer, the final correction is a weak function of frequencynwhen the scattering volume is near the focal area, rather than thenfrequency squared dependence proposed by earlier investigators
机译:提出了一种从脉冲回波测量中获得绝对反向散射系数的新公式。使用该公式,执行衍射校正和系统校准非常简单。定义了用于后向散射系数测量的衍射校正函数和脉冲回波系统的声耦合函数。给出了两种非常有用的情况下这些功能的详细信息:平板传感器和非球面聚焦传感器。还没有提供这些功能的近似值。对于平板换能器,最终配方似乎是对已建立的Sigelmann-Reid配方的修改。对于聚焦换能器,当散射量接近焦点区域时,最终校正是频率的弱函数,而不是早期研究者提出的频率平方相关性