On-load terminal voltage distortion can significantly reduce the flux weakening operation region of electrical machines. This paper investigates the effectiveness of several harmonics reduction methods, e.g., rotor skewing, rotor pole shaping, and stator tooth-tip shaping, on the terminal voltage distortion reduction in fractional slot interior permanent magnet machines. It is found that skewing can only reduce the peak terminal voltages, but not total harmonic distortion, while the average torque is also notably lower. However, on-load terminal voltage distortions can be greatly reduced by rotor pole or stator tooth-tip shaping with only a slight average torque drop. It is found that the local magnetic saturation is largely alleviated based on the magnetic permeance and flux path modification. Finally, these analyses are experimentally validated based on the measured torque speed curves of two prototype machines having the same stator, but different rotors with or without rotor pole shaping.
机译:负载端电压畸变可以显着减小电机的磁通减弱操作区域。本文研究了几种减少谐波的方法,例如转子偏斜,转子磁极整形和定子齿尖整形,对减少分数槽内部永磁电机的端子电压畸变的有效性。发现偏斜只能降低峰值端子电压,而不能降低总谐波失真,而平均扭矩也明显更低。但是,通过转子极或定子齿尖的整形,负载负载端子电压的畸变可以大大降低,而平均转矩下降很小。发现基于磁导率和通量路径的修改,局部磁饱和被大大减轻。最后,这些分析基于具有相同定子但具有或不具有转子磁极成形的不同转子的两个原型机的实测转矩速度曲线进行了实验验证。