首页> 外文期刊>Electromagnetic Compatibility Magazine, IEEE >Examination of contaminant-induced faults in connectors
【24h】

Examination of contaminant-induced faults in connectors

机译:检查连接器中污染物引起的故障

获取原文
获取原文并翻译 | 示例
           

摘要

This paper describes the results of an investigation into the effects of salt water exposure on cable connector impedances. A series of tests were performed to explore the shunting resistance across the pins of wiring harness connectors. The test results show that salt-induced corrosion and moisture may cause intermittent shunting resistances capable of affecting the normal operation of various systems. One important test result is that the induced shunting resistances are a nonlinear function of the applied voltage. This non-linear behavior can be important when evaluating the ESD or radiated RF susceptibility of products that may be exposed to a salt-water environment. An equivalent circuit based on measurements is developed to model the behavior of various salt-water/metal electrode interactions.
机译:本文介绍了盐水暴露对电缆连接器阻抗影响的调查结果。进行了一系列测试以探究线束连接器的插针两端的分流电阻。测试结果表明,盐引起的腐蚀和湿气可能会导致间歇性的分流电阻,从而影响各种系统的正常运行。一个重要的测试结果是,感应的分流电阻是施加电压的非线性函数。当评估可能暴露于盐水环境的产品的ESD或辐射RF磁化率时,这种非线性行为可能很重要。开发了基于测量的等效电路,以对各种盐水/金属电极相互作用的行为进行建模。