Purpose We designed a bi-valve vaginal speculum high-dose-rate (HDR) interstitial gynecologic brachytherapy applicator. This allows for both a direct view of the cervix and image-guided brachytherapy applicator placement. The purpose of this study was to assess the validity of the new applicator. Material and methods The applicator was designed to have a 25-mm arc, which can be spread transversely to 35-mm wide, with 10 insertion holes; it was produced using a stereolithographic printer with biocompatible Dental SG resin. For resin radiodensity was measured in Hounsfield units (HU) using computed tomography (CT). Comparing the new applicator with a conventional intracavitary applicator, we evaluated the treated volume (including dimensions of 100% isodose volume at the central axis), V100/D90/D98 for a hypothetical cervix (a 2-cm-long and 4-cm-diameter cylinder), and dose points of organs at risk (OARs) (at 25 and 30 mm from the tandem). Based on dose-volume histogram (DVH) analysis of the cervix and dose points of OARs, the range of tolerance for the percent dose difference in the prescription dose was set at 5%. Results The mean radiodensity of the Dental SG resin, which was magnetic resonance imaging compatible, was 118 HU. Dimensions of the 100% isodose volume measured at the central axis were 4.4 × 6.6 × 7.4 cm for the new applicator and 4.3 × 6.0 × 7.7 cm for the intracavitary applicator. The 100% prescription dose volumes were 110 cc and 113 cc for the new and conventional applicator, respectively. The percent difference in the hypothetical cervix Vsub100/sub, Dsub90/sub, and Dsub98/sub between the new and intracavitary applicator were within 5%. The percent differences in dose points of OARs at 25 and 30 mm between the new and conventional applicators were within 5%. Conclusions Our speculum applicator can reproduce a conventional pear-shaped dose distribution. Our current clinical practice will use this applicator, which can improve the patient’s treatment results.
机译:目的是设计了一种双瓣膜阴道窥器高剂量率(HDR)间质妇科近距离放射治疗器。这允许宫颈和图像引导的近距离放射治疗器放置的直接视图。本研究的目的是评估新申请人的有效性。材料和方法涂抹器设计成具有25毫米的电弧,可横向于35毫米宽,具有10个插入孔;它是使用具有生物相容性牙科SG树脂的立体化打印机生产。用于使用计算机断层扫描(CT)以Hounsfield单元(HU)测量树脂雷碘。将新的涂抹器与传统的腔内涂药器进行比较,我们评估了经处理的体积(包括在中心轴上的100%体积的尺寸),V100 / D90 / D98,用于假设的子宫颈(2厘米长,4厘米 - 直径气缸),风险(桨)(距离串联25毫米)的器官的剂量点。基于宫颈的剂量直方图(DVH)分析,桨的剂量点,处方剂量百分比百分比的耐受范围设定为5%。结果牙科SG树脂的平均辐射度,磁共振成像兼容,是118胡。在中心轴上测量的100%体积的尺寸为4.4×6.6×7.4cm,用于腔内涂敷器4.3×6.0×7.7厘米。新的和常规涂抹器的100%处方剂量分别为110cc和113cc。新的和腔内涂布器之间假设的子宫颈V ,D 90 和D 98 的百分比差异在5%以内。在新的和常规涂布器之间25和30毫米的桨剂量点的百分比差异在5%以内。结论我们的窥器涂抹器可以再现常规梨形剂量分布。我们目前的临床实践将使用该涂抹器,可以改善患者的治疗结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号