Background:To quantify pharmacological effects on tremor in patients with essential tremor (ET) or Parkinson's Disease (PD), laboratory-grade accelerometers have previously been used. Over the last years, consumer products such as smartphones and smartwatches have been increasingly applied to measure tremor in an easy way. However, it is unknown how the technical performance of these consumer product accelerometers (CPAs) compares to laboratory-grade accelerometers (LGA). This study was performed to compare the technical performance of CPAs with LGA to measure tremor in patients with Parkinson's Disease (PD) and essential tremor (ET).Methods:In ten patients with PD and ten with ET, tremor peak frequency and corresponding amplitude were measured with 7 different CPAs (Apple iPhone 7, Apple iPod Touch 5, Apple watch 2, Huawei Nexus 6P, Huawei watch, mbientlabMetaWear (MW) watch, mbientlab MW clip) and compared to a LGA (Biometrics ACL300) in resting and extended arm position.Results:Both in PD and ET patients, the peak frequency of CPAs did not significantly differ from the LGA in terms of limits of agreement. For the amplitude at peak frequency, only the iPhone and MW watch performed comparable to the LGA in ET patients, while in PD patients all methods performed comparable except for the iPod Touch and Huawei Nexus. Amplitude was higher when measured with distally-located CPAs (Clip, iPhone, iPod) compared with proximally-located CPAs (all watches). The variability between subjects was higher than within subjects for frequency (25.1% vs. 13.4%) and amplitude measurement (331% vs. 53.6%). Resting arm position resulted in lower intra-individual variability for frequency and amplitude (13.4 and 53.5%) compared to extended arm position (17.8 and 58.1%).Conclusions:Peak frequencies of tremor could be measured with all tested CPAs, with similar performance as LGA. The amplitude measurements appeared to be driven by anatomical location of the device and can therefore not be compared. Our results show that the tested consumer products can be used for tremography, allowing at-home measurements, in particular in studies with a cross-over or intra-individual comparison design using the resting arm position.Trial registration:This trial was registered in the Dutch Competent Authority (CCMO) database with number NL60672.058.17 on May 30th 2017.? The Author(s) 2020.
机译:背景:为了量化基本震颤(ET)或帕金森病(PD)患者的震颤的药理作用,先前已经使用了实验室级加速度计。在过去几年中,智能手机和智能手表等消费产品越来越多地应用于以简单的方式测量震颤。然而,尚不清楚这些消费产品加速度计(CPAs)的技术性能如何与实验室级加速度计(LGA)进行比较。进行了本研究以比较CPAS与LGA的技术性能,以测量帕金森病(PD)和基本震颤(ET)的患者震颤(ET)。方法:在10名PD和10患者中,震颤峰值频率和相应的幅度用7个不同的CPAS(Apple iPhone 7,Apple iPod Touch 5,Apple Watch 2,Huawei Nexus 6P,Huawei Watch,MbieteLabetawear(MW)手表,MbieteLab MW Clip),并与LGA(Biometrics ACL300)进行休息和伸展臂相比位置。结果:在PD和ET患者中,CPA的峰值频率与LGA在协议的限制方面没有显着不同。对于峰值频率的振幅,只有与患者的LGA相当的iPhone和MW手表,而在PD患者中只能进行所有方法,除了iPod触摸和华为Nexus之外还进行了可比。与远端CPA(剪辑,iPhone,iPod)相比,与近端的CPAS(所有手表)进行测量时,幅度更高。受试者之间的可变性高于频率的受试者(25.1%与13.4%)和振幅测量(331%vs.53.6%)。与扩展臂位置相比(13.8和58.1%)相比,休息臂位置较低的频率和幅度(13.4和53.5%)的较低的内部变宽。结论:震颤的峰值频率可以用所有测试的CPA测量,具有类似的性能LGA。因此,幅度测量似乎由装置的解剖位置驱动,因此不能进行比较。我们的研究结果表明,经过测试的消费产品可用于颤抖,允许家庭测量,特别是使用静止臂的交叉或单独的比较设计的研究.Trial注册:该试验登记荷兰主管当局(CCMO)数据库,2017年5月30日与N160672.058.17。作者2020年。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号