Purpose: To review refractive, visual acuity, defocus curve and subjective visual quality results after bilateral implantation of an apodized diffractive toric intraocular lens (IOL) with a moderate add in the dominant eye and a higher add in the non-dominant eye. Setting: One site in Gainesville, GA, USA. Design: Single arm, non-randomized prospective study. Methods: This was a single-arm prospective study of visual acuity and subjective visual quality after implantation of a toric low-add apodized diffractive multifocal IOL in the dominant eye and a higher add IOL of the same type in the non-dominant eye three months after surgery. Binocular visual acuity at 4 m, 60 cm and 40 cm was tested. Other tests included refraction, defocus curve measurement and evaluation of the quality of vision. Toric IOL orientation was also measured. Results: A total of 29 subjects were enrolled. There were no statistically?significant differences in the mean keratometry, corneal astigmatism or IOL sphere power implanted in the dominant and non-dominant eyes. Vision was preferred without any correction in more than half of the eyes tested (32/58, 55%). The residual refractive astigmatism was ≤ 0.50 D in 100% of eyes. Seventy-five percent of subjects (22/29) had 0.10 logMAR (20/25 Snellen) binocular uncorrected visual acuity at all tested distances. Glare and haloes were the most common visual disturbances, but most subjects (22/29, 76%) reported that they were not bothered by any visual disturbances. In 97% of eyes (56/58), the measured difference in orientation between 1 month and 3 months was less than 5 degrees, with no change more than 14 degrees. Conclusion: This blended bifocal IOL modality appears to be well-tolerated by subjects with a good range of vision and minimal bother from visual disturbances.
机译:目的:审查折射,视力,散焦曲线和主观视觉质量,在双边植入减少的衍射背心眼透镜(IOL)的双边植入中,中度较高的add,在非显着的眼睛中的增加和更高的添加中。环境:美国盖斯维尔的一个网站,美国。设计:单臂,非随机预期研究。方法:这是在主导眼中植入TORIC低添加衍射多焦体IOL之后的视力和主观视觉质量的单架前瞻性研究,在三个月的非显性眼中的相同类型的高度添加IOL手术后。测试4米,60厘米和40cm处的双目视觉。其他测试包括折射,散焦曲线测量和评估视觉质量。还测量了复活IOL取向。结果:共有29个科目。毫无统计学?植入主导和非显着眼睛的平均角膜测量,角膜散散或IOL球体的显着差异。视觉是优选的,没有超过一半的眼睛测试(32/58,55%)。在100%的眼睛中,残留折射率≤0.50d。在所有测试的距离都有75%的受试者(22/29)具有0.10个Logmar(20/25 snellen)双目未矫正的视力。眩光和晕是最常见的视觉紊乱,但大多数科目(22/29,76%)报告说,他们并不被任何视觉紊乱困扰。在97%的眼睛(56/58)中,1个月和3个月之间的取向差异小于5度,没有变化超过14度。结论:这种混合的双焦质IOL模块似乎受到良好视觉范围和视觉扰动的最小困难的受试者充分容忍。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号