首页> 外文期刊>Journal of Clinical Microbiology >Spread of Pseudomonas fluorescens Due to Contaminated Drinking Water in a Bone Marrow Transplant Unit
【24h】

Spread of Pseudomonas fluorescens Due to Contaminated Drinking Water in a Bone Marrow Transplant Unit

机译:饮用水中污染的荧光假单胞菌在骨髓移植单元中的传播

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Pseudomonas infections are an important cause of morbidity and mortality in immunocompromised patients. We present here data for the spread of Pseudomonas fluorescens caused by a contaminated drinking water dispenser in a bone marrow transplant unit. Over a 1-month period we observed a sharp increase in the isolation of P. fluorescens from weekly pharyngeal surveillance swabs. Environmental samples were taken from a variety of water sources throughout the unit. These samples were cultured on cetrimide agar medium, and isolates were epidemiologically characterized by antibiotic susceptibility patterns and molecular typing methods. Nine patients became colonized with P. fluorescens, and six out of the nine developed febrile neutropenia. P. fluorescens was cultured after the filtration of 100 ml of drinking water from one of two stand-alone chiller units supplying cooled bottled water to the bone marrow transplant unit. All other environmental samples were negative. There were no further cases of P. fluorescens colonization after the contaminated dispenser was removed. Molecular typing showed that all P. fluorescens isolates were identical by both random amplification of polymorphic DNA PCR and pulsed-field gel electrophoresis. We recommend that such bottled water supplies not be used in high-risk areas or be subject to regular microbiological monitoring.
机译:假单胞菌感染是免疫受损患者发病和死亡的重要原因。我们在这里提供的数据是由骨髓移植装置中的饮用水分配器污染引起的荧光假单胞菌的扩散。在1个月的时间内,我们观察到每周一次的咽部监测拭子分离出的荧光假单胞菌急剧增加。从整个装置的各种水源中采集环境样品。这些样品在西曲美琼脂培养基上培养,并通过抗生素敏感性模式和分子分型方法对分离株进行流行病学表征。 9名患者被荧光假单胞菌定植,9名患者中有6名发展为发热性中性粒细胞减少症。在从两个独立的冷却器单元之一过滤出100毫升饮用水后,培养了荧光假单胞菌,该冷却器单元向骨髓移植单元提供了冷却的瓶装水。所有其他环境样品均为阴性。移除受污染的分配器后,没有再出现荧光假单胞菌定植的情况。分子分型显示,通过多态性DNA PCR的随机扩增和脉冲场凝胶电泳,所有荧光假单胞菌分离物均相同。我们建议不要在高风险地区使用此类瓶装水,也不要对其进行定期微生物监测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号