...
首页> 外文期刊>Journal of Clinical Microbiology >Rapid Detection of Shiga Toxin-Producing Escherichia coli by Optical Immunoassay
【24h】

Rapid Detection of Shiga Toxin-Producing Escherichia coli by Optical Immunoassay

机译:光学免疫分析法快速检测产志贺毒素的大肠杆菌

获取原文
           

摘要

In a multi-health center study, a new rapid optical immunoassay (OIA) for the detection of Shiga toxin types 1 and 2, the BioStar OIA SHIGATOX kit (Inverness Medical Professional Diagnostics, Inc.), was used to prospectively screen 742 fresh fecal samples for Shiga toxins in parallel with the Premier enterohemorrhagic Escherichia coli (EHEC) kit (Meridian BioScience, Inc.) with and without enrichment of the specimens by incubation in MacConkey broth. Additionally, 85 previously tested frozen fecal samples were assessed as described above. All positive immunoassay results were confirmed by the Vero cell cytotoxicity assay. A further modification of the screening procedure was evaluated on 470 of the prospectively screened specimens. Swabs of growth from conventionally plated stool culture media were subjected to the OIA SHIGATOX, and results were compared with those obtained with the Premier EHEC kit following broth enrichment. Overall, the OIA SHIGATOX kit was significantly more sensitive than the Premier EHEC kit on fresh direct stool specimens (sensitivities, 96.8% and 83.9%, respectively; P < 0.05). The two assays performed equally well with each other on frozen and broth-enriched samples. The colony sweep method used in conjunction with the OIA kit was somewhat more effective at detection of Shiga toxins from growth on agar than the overnight broth enrichment procedure used with the Premier EHEC assay (sensitivities, 100% and 92%, respectively; P < 0.09). Overall, the OIA SHIGATOX kit provided rapid, easy-to-interpret results and was highly effective at detection of Shiga toxin-producing E. coli in fecal samples and overnight cultures.
机译:在一个多健康中心的研究中,使用了一种新的快速光学免疫测定法(OIA),用于检测1型和2型志贺毒素,BioStar OIA SHIGATOX试剂盒(Inverness Medical Professional Diagnostics,Inc.)用于前瞻性筛查742个新鲜粪便。与志贺肠出血性大肠杆菌(EHEC)试剂盒(Meridian BioScience,Inc.)平行的志贺毒素样品,可在MacConkey肉汤中温育,也可不进行温育。另外,如上所述评估了85个先前测试的冷冻粪便样品。 Vero细胞的细胞毒性试验证实了所有阳性免疫分析结果。筛选程序的进一步修改是在470个预期筛选的样本上进行的。将来自常规平板粪便培养基的生长拭子置于OIA SHIGATOX中,并将结果与​​肉汤富集后使用Premier EHEC试剂盒获得的结果进行比较。总体而言,对于新鲜的直接粪便标本,OIA SHIGATOX试剂盒比Premier EHEC试剂盒的敏感性要高得多(灵敏度分别为96.8%和83.9%; P <0.05)。两种测定法在冷冻和肉汤富集的样品上的效果均相同。与OIA试剂盒结合使用的菌落清扫方法比在Premier EHEC分析中使用的过夜肉汤富集程序更有效地检测琼脂上的志贺毒素(敏感性分别为100%和92%; P <0.09)。总体而言,OIA SHIGATOX试剂盒提供了快速,易于理解的结果,并且在检测产生志贺毒素的 E方面非常有效。粪便样本和过夜培养物中的大肠杆菌

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号