Daptomycin is a lipopeptide antibiotic with activity against several important gram-positive bacterial pathogens, including drug-resistant staphylococci and enterococci. Because the mechanism of action of daptomycin is calcium-dependent depolarization of the cell membrane, susceptibility testing requires medium supplemented with a physiological level of calcium. This study assessed two Food and Drug Administration-cleared commercial test devices for determination of daptomycin MICs, Etest and JustOne. A collection of 220 selected isolates, including Staphylococcus aureus, coagulase-negative staphylococci, Enterococcus faecalis, E. faecium, E. avium, E. durans, E. casseliflavus, and E. gallinarum, were tested by both methods. Included in the collection were 22 S. aureus and 14 Enterococcus sp. isolates that were recovered from patients and were nonsusceptible on the basis of the daptomycin MICs. As the reference method for comparison, all isolates were tested by the Clinical and Laboratory Standards Institute broth microdilution method incorporating cation-adjusted Mueller-Hinton broth with 50 μg/ml calcium. Daptomycin MICs agreed, within 1 twofold dilution, for 97% of the isolates by Etest and for 100% by JustOne. However, daptomycin MICs determined by Etest were 1 dilution lower than the reference MICs for 65% of the Enterococcus sp. isolates tested. This resulted in 28.5% very major (VM) errors (4/14) with enterococci (all E. faecium) but none (0/22) with staphylococci. Use of JustOne yielded MICs that were 1 dilution lower than the reference MICs for 69% of the staphylococci and 25% of the enterococci. This resulted in 13.6% VM errors (3/22) with staphylococci and 14.3% VM errors (2/14) with enterococci. The manufacturer-recommended JustOne inoculum preparation resulted in mean colony counts of only 5 × 104 to 1 × 105 CFU/ml in the wells of the strip. Increasing the inoculum to 3 × 105 to 4 × 105 CFU/ml eliminated two of five VM errors upon retesting. No major interpretive errors occurred with either device. In summary, daptomycin MICs generated by the Etest or JustOne method generally agreed within 1 dilution of the reference daptomycin MICs. However, both devices produced slightly lower MICs that resulted in some VM errors.
机译:达托霉素是一种脂肽抗生素,对几种重要的革兰氏阳性细菌病原体具有活性,包括耐药性葡萄球菌和肠球菌。因为达托霉素的作用机理是细胞膜的钙依赖性去极化,所以药敏试验需要添加生理水平的钙的培养基。这项研究评估了食品和药物管理局批准的两种用于确定达托霉素MIC的商业测试设备Etest和JustOne。收集了220种分离株,包括金黄色葡萄球菌,凝固酶阴性葡萄球菌,肠球菌 E。粪便 E。 avium E。 durans E。 casseliflavus E。两种方法都对鸡胆进行了测试。集合中包含22个 S。金黄色葡萄球菌和14个肠球菌 sp。从患者中回收的分离物,根据达托霉素MICs不敏感。作为比较的参考方法,所有分离物均通过临床和实验室标准协会的肉汤微稀释方法进行测试,该方法结合了阳离子调节的Mueller-Hinton肉汤和50μg/ ml钙。 Daptomycin MIC同意在1倍稀释度内通过Etest获得97%的分离物,通过JustOne获得100%的分离物。但是,对于65%的肠球菌 sp,通过Etest测定的达托霉素MIC比参考MIC低1倍。分离株经过测试。这导致肠球菌(全部为 E。faecium )出现28.5%的重大错误(VM)(4/14),而葡萄球菌无(0/22)。对于69%的葡萄球菌和25%的肠球菌,使用JustOne产生的MIC比参考MIC低1倍。葡萄球菌导致13.6%的VM错误(3/22),肠球菌导致14.3%的VM错误(2/14)。制造商推荐的JustOne接种物制备条带孔中的平均菌落数仅为5×10 4 至1×10 5 CFU / ml。重新接种后,将接种量增加至3×10 5 至4×10 5 CFU / ml,可以消除五个VM错误中的两个。两种设备均未发生重大解释错误。总之,通过Etest或JustOne方法生成的达托霉素MIC通常在参考达托霉素MIC的1倍稀释度内一致。但是,两个设备产生的MIC都略低,从而导致了一些VM错误。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号