摘要

Separation and storage of plasma within 2 h of phlebotomy is required for the VACUTAINER PPT Plasma Preparation Tube (PPT) versus 4 h for the predecessor VACUTAINER EDTA tube for human immunodeficiency virus type 1 (HIV-1) viral load (HIVL) testing by the VERSANT HIV-1 RNA 3.0 assay (branched DNA). The 2-h limit for PPT imposes time constraints for handling and transporting to the testing laboratory. This study compares HIVL reproducibility from matched blood in EDTA tubes and PPTs and between PPT pairs following processing within 4 h of phlebotomy, stability of plasma HIV-1 RNA at 24- and 72-h room temperature storage in the tube, and comparative labor and supply requirements. Blood from 159 patients was collected in paired tubes (EDTA/PPT or PPT/PPT): 86 paired EDTA tubes and PPTs were processed 4 h following phlebotomy and their HIVLs were compared, 42 paired PPT/PPT pairs were analyzed for intertube HIVL reproducibility, and 31 PPT/PPT pairs were analyzed for HIV-1 RNA stability by HIVL. Labor and supply requirements were compared between PPT and EDTA tubes. PPTs produce results equivalent to standard EDTA tube results when processed 4 h after phlebotomy. PPT intertube analyte results are reproducible. An average decrease of 13% and 37% in HIVL was observed in PPT plasma after 24 and 72 h of room temperature storage, respectively; thus, plasma can be stored at room temperature up to 24 h in the original tube. PPTs offer labor and supply savings over EDTA tubes.
机译:对于VACUTAINER PPT血浆制备管(PPT),需要在放血2小时内分离和保存血浆,而对于以前的VACUTAINER EDTA管,则需要进行4小时的人类1型免疫缺陷病毒(HIV-1)病毒载量(HIVL)检测, VERSANT HIV-1 RNA 3.0检测(分支的DNA)。 PPT的2小时限制规定了处理和运输到测试实验室的时间限制。这项研究比较了EDTA试管和PPT中以及在放血后4小时内处理后的PPT对之间匹配血液中的HIVL再现性,在试管中室温保存24和72 h时血浆HIV-1 RNA的稳定性以及比较人工和供应要求。将159例患者的血液收集在成对的试管(EDTA / PPT或PPT / PPT)中:配对的EDTA管86和PPT在放血后4小时进行处理,并比较其HIVL,分析了42对PPT / PPT对的管间HIVL可重复性,通过HIVL分析了31对PPT / PPT对的HIV-1 RNA稳定性。比较了PPT和EDTA管的人工和供应要求。在放血后4小时进行处理时,PPT产生的结果等同于标准EDTA管的结果。 PPT管间分析物的结果可重复。室温保存24小时和72小时后,PPT血浆中HIVL的平均下降分别为13%和37%。因此,血浆可以在室温下长达24小时的原始管中存储。 PPT较EDTA管节省了劳动力和供应。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号