...
首页> 外文期刊>Journal of Clinical Microbiology >Direct Comparison of the BACTEC 9240 and BacT/ALERT 3D Automated Blood Culture Systems for Candida Growth Detection
【24h】

Direct Comparison of the BACTEC 9240 and BacT/ALERT 3D Automated Blood Culture Systems for Candida Growth Detection

机译:BACTEC 9240和BacT / ALERT 3D自动化血液培养系统用于念珠菌生长检测的直接比较

获取原文
           

摘要

A direct comparison of two automated blood culture systems was conducted to compare their ability to detect Candida growth. The systems evaluated were the BACTEC 9240 (Bactec) and BacT/ALERT 3D (BacT). The aerobic, anaerobic, and mycology media for each system were evaluated: Bactec Plus Aerobic/F, Plus Anaerobic/F, and Myco/F Lytic bottles,, respectively, and BacT FA, SN, and MB bottles, respectively. Each blood culture bottle was inoculated with fresh blood from healthy donors. Fifty isolates of Candida spp. were used. The six different blood culture bottles were each inoculated with 1,000 yeasts per bottle and then incubated in the corresponding automated system. The BacT detected growth of 90% (135 of 150) of Candida pathogens, while Bactec detected 66% (100 of 150). Growth was detected in all BacT and Bactec mycology bottles, all BacT aerobic bottles, and by terminal subculture of all bottles. Sixty-five of 300 (22%) bottles had no growth detected; 50 from the Bactec (5 aerobic and 45 anaerobic) and 15 from the BacT (all anaerobic). Terminal subculture of “negative” bottles demonstrated viable yeast growth from all 65 bottles, representing 65 false-negatives. The mean time to growth detection in the BacT system was 25.62 h while the Bactec was 27.30 h (P < 0.01). Both automated blood culture systems detected all episodes of simulated candidemia when specialized mycology media were used. However, when only standard aerobic and anaerobic media were used, the BacT performed better than the Bactec in overall growth detection, time to growth detection, and number of false-negatives.
机译:直接比较了两个自动血液培养系统,以比较它们检测 Candida 生长的能力。评估的系统是BACTEC 9240(Bactec)和BacT / ALERT 3D(BacT)。评估每个系统的需氧,厌氧和真菌学培养基:分别为Bactec Plus有氧/ F,Plus厌氧/ F和Myco / F Lytic瓶,以及分别为BacT FA,SN和MB瓶。每个血培养瓶均接种了来自健康供体的新鲜血液。 50株 Candida spp。被使用。六个不同的血液培养瓶每个均接种1,000个酵母,然后在相应的自动化系统中孵育。 BacT检测到90%(150个中的135个) Candida 病原体的生长,而Bactec检测到66%(150个中的100个)的病原体。在所有BacT和Bactec真菌学瓶,所有BacT有氧瓶中以及所有瓶的终代继代培养中均检测到生长。 300瓶中有65瓶(22%)未检测到增长; 50个来自Bactec(5个需氧和45个厌氧)和15个来自BacT(所有厌氧)。 “阴性”瓶的终代传代培养表明,在所有65瓶中,代表65个假阴性的酵母中都有可行的酵母菌生长。 BacT系统中检测到生长的平均时间为25.62小时,而Bactec为27.30小时( P <0.01)。当使用专门的真菌学培养基时,两个自动血液培养系统都检测到所有模拟念珠菌血症发作。但是,当仅使用标准需氧和厌氧培养基时,BacT在总体生长检测,生长时间检测和假阴性数量方面的表现要优于Bactec。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号