首页> 外文期刊>Journal of Clinical Microbiology >Correlation between Microdilution, E-test, and Disk Diffusion Methods for Antifungal Susceptibility Testing of Posaconazole against Candida spp.
【24h】

Correlation between Microdilution, E-test, and Disk Diffusion Methods for Antifungal Susceptibility Testing of Posaconazole against Candida spp.

机译:微稀释,E检验和纸片扩散方法之间的关系,用于泊沙康唑对念珠菌的抗真菌药敏试验。

获取原文
           

摘要

Agar-based antifungal susceptibility testing is an attractive alternative to the microdilution method. We examined the correlation between the microdilution, E-test, and disk diffusion methods for posaconazole against Candida spp. A total of 270 bloodstream isolates of Candida spp. with a broad range of posaconazole MICs were tested using the CLSI M27-A2 method for microdilution, as well as the M-44A method and E-test methods for agar-based testing on Mueller-Hinton agar supplemented with 2% glucose and 0.5 μg of methylene blue. MICs and inhibitory zone diameters at the prominent growth reduction endpoint were recorded at 24 and 48 h. The Candida isolates included Candida albicans (n = 124), C. parapsilosis (n = 44), C. tropicalis (n = 41), C. glabrata (n = 36), C. krusei (n = 20), C. lusitaniae (n = 3), and C. dubliniensis (n = 2). The overall concordance (i.e., the percentage of isolates within two dilutions) between the E-test and microdilution was 64.8% at 24 h and 82.6% at 48 h. When we considered an arbitrary breakpoint of ≤1 μg/ml, the agreement between the E-test and microdilution methods was 87.8% at 24 h and 93.0% at 48 h. The correlation of MICs with disk diffusion zone diameters was better for the E-test than the microdilution method. Zone correlation for diameters produced by the disks of two manufacturers was high, with a Pearson test value of 0.941 at 24 h. The E-test and microdilution MICs show good concordance and interpretative agreement. The disk diffusion zone diameters are highly reproducible and correlate well with both the E-test and the microdilution method, making agar-based methods a viable alternative to microdilution for posaconazole susceptibility testing.
机译:基于琼脂的抗真菌药敏试验是微稀释法的一种有吸引力的替代方法。我们研究了泊沙康唑对 Candida spp的微量稀释,E检验和圆盘扩散方法之间的相关性。共有270种 Candida spp血流分离株。使用CLSI M27-A2方法进行微量稀释,并使用M-44A方法和E-test方法对补充2%葡萄糖和0.5μg葡萄糖的Mueller-Hinton琼脂进行测试,测定了多种泊沙康唑的MIC亚甲蓝。在第24和48小时记录MIC和显着的生长减少终点处的抑制区直径。 Candida 分离株包括白色念珠菌 n = 124), C。副瘫痪 n = 44), C。 Tropicalis n = 41), C。 glabrata n = 36), C。 krusei n = 20), C。 lusitaniae n = 3)和 C。 dubliniensis n = 2)。 E-检验和微量稀释之间的总体一致性(即两种稀释液中分离物的百分比)在24小时时为64.8%,在48小时时为82.6%。当我们认为≤1μg/ ml的任意断点时,E检验和微量稀释方法之间的一致性在24 h时为87.8%,在48 h时为93.0%。与微稀释法相比,E测试的MIC与圆盘扩散区直径的相关性更好。两家制造商生产的圆盘的直径区域相关性很高,在24小时内的皮尔逊测试值为0.941。 E检验和微量稀释MIC显示出良好的一致性和解释性一致性。圆盘扩散区的直径可高度重现,并且与E检验和微量稀释方法都具有很好的相关性,从而使琼脂基方法成为泊沙康唑药敏试验中微量稀释的可行替代方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号