首页> 外文期刊>Journal of Clinical Microbiology >Comparison of Phoenix and VITEK 2 Extended-Spectrum-β-Lactamase Detection Tests for Analysis of Escherichia coli and Klebsiella Isolates with Well-Characterized β-Lactamases
【24h】

Comparison of Phoenix and VITEK 2 Extended-Spectrum-β-Lactamase Detection Tests for Analysis of Escherichia coli and Klebsiella Isolates with Well-Characterized β-Lactamases

机译:Phoenix和VITEK 2广谱β-内酰胺酶检测方法的比较,用于分析大肠杆菌和克雷伯菌的特征明确的β-内酰胺酶

获取原文
           

摘要

The VITEK 2 and Phoenix extended-spectrum β-lactamase (ESBL) detection systems, which comprise confirmatory tests and expert systems, were evaluated for their ability to discriminate between 102 well-characterized strains of ESBL-positive or -negative Escherichia coli, Klebsiella pneumoniae, and Klebsiella oxytoca. At least 38 distinct ESBLs were included. The strains were chosen to include some known to cause false-positive and false-negative CLSI ESBL confirmatory test results. Therefore, enzyme characterizations, rather than CLSI tests, were the reference methods for the Phoenix and VITEK 2 evaluations. A third arm of the study was conducted with the Phoenix test using two normally inactive expert rules intended to enhance ESBL detection, in addition to using the currently available software. The Phoenix ESBL confirmatory test and unmodified expert system exhibited 96% sensitivity and 81% specificity for ESBL detection. Activation of the two additional rules increased sensitivity to 99% but reduced the specificity to 58%. The VITEK 2 ESBL confirmatory test exhibited 91% sensitivity, which was reduced to 89% sensitivity by its expert system, while its specificity was 85%. Many of the expert system interpretations of both instruments were helpful, but some were suboptimal. The VITEK 2 expert system was potentially more frustrating because it provided more inconclusive interpretations of the results. Considering the high degree of diagnostic difficulty posed by the strains, both ESBL confirmatory tests were highly sensitive. The expert systems of both instruments require modification to update and enhance their utility.
机译:评估了VITEK 2和Phoenix广谱β-内酰胺酶(ESBL)检测系统(包括验证性测试和专家系统),以区分102种特征明确的ESBL阳性或阴性大肠杆菌菌株。 肺炎克雷伯菌产酸克雷伯菌。至少包括38个不同的ESBL。选择的菌株包括已知会导致假阳性和假阴性的CLSI ESBL确认测试结果的菌株。因此,酶的表征而不是CLSI测试是Phoenix和VITEK 2评估的参考方法。该研究的第三部分是通过Phoenix测试进行的,除了使用当前可用的软件外,还使用两个通常不活动的专家规则来增强ESBL检测。 Phoenix ESBL验证性测试和未修改的专家系统对ESBL检测显示96%的灵敏度和81%的特异性。激活这两个附加规则将灵敏度提高到99%,但特异性降低到58%。 VITEK 2 ESBL确认测试显示出91%的灵敏度,通过其专家系统降低到89%的灵敏度,而特异性为85%。两种仪器的许多专家系统解释都是有帮助的,但有些不是最佳的。 VITEK 2专家系统可能会更令人沮丧,因为它对结果提供了更加不确定的解释。考虑到菌株造成的高度诊断难度,两种ESBL确证试验均高度敏感。两种仪器的专家系统都需要修改以更新和增强其实用性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号