Nosocomial Pneumonia Caused by Three Genetically Different Strains of Legionella pneumophila and Detection of These Strains in the Hospital Water Supply

机译:三种遗传性嗜肺军团菌菌株引起的医院内肺炎及医院供水中这些菌株的检测

获取原文
           

摘要

A 44-year-old woman developed Legionella pneumophilapneumonia after cerebral surgery. Initially, one colony from a clinical specimen and two colonies from water samples, all belonging to serogroup 12, did not match when their DNA restriction patterns were compared. When additional colonies from the water specimens were analyzed, a serogroup 12 strain complementary to that found in the clinical specimen was identified. Other colonies from the clinical specimen were identified as serogroup 12 strains complementary to those identified from the water. In addition, the same serogroup 1 strain was isolated from the patient and the water system.
机译:一名44岁的妇女在进行脑部手术后患上了肺炎军团菌(Legionella pneumophila)肺炎。最初,当比较它们的DNA限制模式时,来自临床标本的一个菌落和来自水样品的两个菌落均属于血清群12,它们不匹配。当对水标本中的其他菌落进行分析时,鉴定出了与临床标本中发现的血清群互补的12型菌株。来自临床标本的其他菌落被鉴定为血清群12株,与从水中鉴定出的菌群互补。另外,从患者和水系统中分离出相同的血清群1菌株。