首页> 外文期刊>Journal of Clinical Microbiology >Evaluation of a Novel Automated Chemiluminescent Assay System for Antimicrobial Susceptibility Testing
【24h】

Evaluation of a Novel Automated Chemiluminescent Assay System for Antimicrobial Susceptibility Testing

机译:新型自动化化学发光检测系统对抗菌药敏感性试验的评估

获取原文
           

摘要

The newly developed Rapid Lumi Eiken/IS60 (RL/IS60) system automatically determines MICs by detecting chemiluminescence produced in the reaction of a chemiluminescent probe and oxygen metabolites from living microorganisms. The present study evaluated this system for accuracy in antimicrobial susceptibility testing. Chemiluminescence intensities after 4 h of cultivation of clinically important strains were plotted against various concentrations of antimicrobial agents, which resulted in curves reflecting the levels of susceptibility. Sixty-percent inhibitory concentrations based on the susceptibility curves agreed with MICs determined by the reference microdilution method. When the MICs of antimicrobial agents for four quality control (QC) strains (Staphylococcus aureus, Enterococcus faecalis, Escherichia coli, and Pseudomonas aeruginosa) were determined by the RL/IS60 system, most (91.1%) of them were within the QC limits proposed by the National Committee for Clinical Laboratory Standards. The system was further assessed for a total of 162 clinical isolates, including E. coli, Citrobacter freundii, Enterobacter cloacae, Klebsiella pneumoniae, Serratia marcescens, Proteus mirabilis, Morganella morganii, P. aeruginosa, Haemophilus influenzae, S. aureus, coagulase-negative staphylococci, Enterococcus faecalis, Enterococcus faecium, and Streptococcus pneumoniae. Overall, there was 90.6% agreement between the RL/IS60 system and the reference microdilution method. Our results suggest that the RL/IS60 system provides rapid and reliable MICs of a variety of antimicrobial agents for clinical isolates as well as QC strains.
机译:新开发的Rapid Lumi Eiken / IS60(RL / IS60)系统通过检测化学发光探针与来自活微生物的氧代谢物反应产生的化学发光来自动确定MIC。本研究评估了该系统在抗菌药敏试验中的准确性。将培养重要临床菌株的4小时后的化学发光强度与各种浓度的抗微生物剂作图,得出反映敏感性水平的曲线。根据药敏曲线得出的抑制浓度为60%,与通过参考微量稀释法测定的MIC一致。当四个质量控制(QC)菌株(金黄色葡萄球菌肠球菌大肠埃希氏菌假单胞菌)的抗菌药物的MIC时铜绿假单胞菌是由RL / IS60系统确定的,其中大多数(91.1%)均在国家临床实验室标准委员会提议的质量控制范围内。该系统进一步评估了包括em在内的总共162种临床分离株。大肠杆菌弗氏柠檬酸杆菌,<泄殖腔肠杆菌肺炎克雷伯菌粘质沙雷氏菌变形杆菌mirabilis 摩根氏摩根菌 P。铜绿菌流感嗜血杆菌 S。金黄色葡萄球菌,凝固酶阴性葡萄球菌,粪肠球菌,粪肠球菌和肺炎链球菌。总体而言,RL / IS60系统与参考微稀释方法之间的一致性达到90.6%。我们的结果表明,RL / IS60系统可为临床分离株和QC菌株提供各种抗菌剂的快速可靠的MIC。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号