Exploiting the high sensitivity of the chemiluminescence phenomenon, an accurate and sensitive point-of-care test, called the ZstatFlu-II test (ZymeTx, Inc., Oklahoma City, Okla.), was developed to detect influenza virus infections. The ZstatFlu-II test takes 20 min and requires approximately 2 min of “hands-on” time for operational steps. The ZstatFlu-II test does not distinguish between infections with influenza virus types A and B. ZstatFlu-II test results are printed on Polaroid High-Speed Detector Film, allowing test results to be archived. A prototype version of the ZstatFlu-II test was evaluated during the 2000-to-2001 flu season with 300 nasal aspirate specimens from children at a pediatric hospital. Compared to culture, the ZstatFlu-II test had 88% sensitivity and 92% specificity. The Directigen test had a sensitivity of 75% and a specificity of 93%. The sensitivity of the ZstatFlu-II test was significantly higher than that of the Directigen test (P < 0.0574).
机译:利用化学发光现象的高灵敏度,开发了一种准确而灵敏的即时检验,称为ZstatFlu-II测试(ZymeTx,Inc.,俄克拉荷马州俄克拉荷马州),用于检测流感病毒感染。 ZstatFlu-II测试需要20分钟,大约需要2分钟的“动手”时间才能完成操作步骤。 ZstatFlu-II测试不能区分A型和B型流感病毒。ZstatFlu-II测试结果打印在宝丽来高速检测膜上,可以将测试结果存档。 ZstatFlu-II测试的原型版本在2000年至2001年的流感季节期间,对儿科医院儿童的300份鼻腔吸出标本进行了评估。与培养相比,ZstatFlu-II测试的灵敏度为88%,特异性为92%。 Directigen测试的灵敏度为75%,特异性为93%。 ZstatFlu-II测试的灵敏度显着高于Directigen测试的灵敏度( P <0.0574)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号