...
首页> 外文期刊>Journal of Clinical Microbiology >Comparison between the LCx Probe System and the COBAS AMPLICOR System for Detection of Chlamydia trachomatisand Neisseria gonorrhoeae Infections in Patients Attending a Clinic for Treatment of Sexually Transmitted Diseases in Amsterdam, The Netherlands
【24h】

Comparison between the LCx Probe System and the COBAS AMPLICOR System for Detection of Chlamydia trachomatisand Neisseria gonorrhoeae Infections in Patients Attending a Clinic for Treatment of Sexually Transmitted Diseases in Amsterdam, The Netherlands

机译:LCx探针系统与COBAS AMPLICOR系统在前往荷兰阿姆斯特丹治疗性传播疾病的门诊患者中检测沙眼衣原体和淋病奈瑟菌感染的比较

获取原文
           

摘要

Two assays for the detection of Chlamydia trachomatisand Neisseria gonorrhoeae were compared: the LCx Probe system (the LCx system; Abbott Diagnostic Laboratories, North Chicago, Ill.) and the COBAS AMPLICOR C. trachomatis/N. gonorrhoeae system (the COBAS AMPLICOR system; Roche Diagnostic Systems, Branchburg, N.J.). Endocervical swab specimens, male urethral swab specimens, and female and male urine specimens were collected from 503 female and 498 male visitors attending a sexually transmitted diseases clinic in Amsterdam, The Netherlands. Prevalences for C. trachomatis were 12.5% (63 of 503) and 10.0% (50 of 498) in females and males, respectively. The prevalences for N. gonorrhoeae were 1.2% (6 of 503) and 4.2% (21 of 498) in females and males, respectively. Both assays showed high values for sensitivity and specificity with regard to the detection of C. trachomatis in endocervical swab specimens, male urethral swab specimens, and female and male urine specimens. The sensitivities for the LCx system were 92.1, 90.0, 88.9, and 94.0% for each type of specimen, respectively; and the sensitivies for the COBAS AMPLICOR system were 96.8, 98.0, 82.5, and 92.0% for each type of specimen, respectively. Specificities ranged between 98.4 and 100%. The sensitivity of the LCx system for the detection of N. gonorrhoeae was 100% for female cervical swab and urine specimens and male urethral swab specimens, while for male urine specimens the sensitivity was 95.2%; the specificity was 100% for all types of specimens. For the detection of N. gonorrhoeae by the COBAS AMPLICOR assay, the sensitivity for female cervical swab and male urethral swab specimens was 100%, that for female urine specimens was 66.7%, and that for male urine specimens was 95.2%. However, the predictive values of a positive test for female cervical swab specimens and urine specimens were 31.6 and 36.4%, respectively. Sequence analysis of the amplimers obtained by an in-house 16S rRNA PCR of the solely COBAS AMPLICOR system-positive swab specimens revealed neitherN. gonorrhoeae nor other Neisseria spp. The COBAS AMPLICOR assay was considered not suitable for screening for infections with N. gonorrhoeae. If this assay is used for detection of N. gonorrhoeae, confirmation of positive results by a reliable test is mandatory.
机译:比较了两种检测沙眼衣原体和淋病奈瑟氏菌的方法:LCx探针系统(LCx系统;伊利诺伊州北芝加哥的雅培诊断实验室)和COBAS放大器 C。沙眼/ N。淋病菌系统(COBAS AMPLICOR系统; Roche Diagnostic Systems,Branchburg,N.J。)。从荷兰阿姆斯特丹一家性病门诊的503名女性和498名男性访客中收集了宫颈拭子标本,男性尿道拭子标本以及男女尿液标本。 C的患病率。女性和男性沙眼分别为12.5%(503的63)和10.0%(50的498)。 N的患病率。女性和男性的淋病菌分别为1.2%(503人中有6人)和4.2%(498人中有21人)。两种测定均显示出与检测 C有关的高灵敏度和特异性值。宫颈内拭子标本,男性尿道拭子标本以及女性和男性尿液标本中的沙眼。对于每种样品,LCx系统的灵敏度分别为92.1%,90.0、88.9和94.0%。每种样品的COBAS AMPLICOR系统的灵敏度分别为96.8%,98.0、82.5和92.0%。特异性在98.4至100%之间。 LCx系统检测 N的灵敏度。女性宫颈拭子和尿液标本以及男性尿道拭子标本的淋病菌检出率为100%,而男性尿液标本的敏感度为95.2%。所有类型标本的特异性均为100%。用于检测 N。用COBAS AMPLICOR分析淋球菌,雌性宫颈拭子和雄性尿道拭子样本的敏感性为100%,雌性尿液样本的敏感性为66.7%,雄性尿液样本的敏感性为95.2%。但是,女性宫颈拭子样本和尿液样本阳性检测的预测值分别为31.6%和36.4%。通过对单独的COBAS AMPLICOR系统阳性拭子样本进行内部16S rRNA PCR获得的扩增子的序列分析均未显示。淋病科或其他奈瑟菌 spp。认为COBAS AMPLICOR分析法不适合筛查 N感染。淋病菌。如果此测定法用于检测 N。淋球菌,必须通过可靠的测试确认阳性结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号