首页> 外文期刊>Journal of Clinical Microbiology >Results of Human Papillomavirus DNA Testing with the Hybrid Capture 2 Assay Are Reproducible
【24h】

Results of Human Papillomavirus DNA Testing with the Hybrid Capture 2 Assay Are Reproducible

机译:用混合捕获2检测法检测人乳头瘤病毒DNA的结果可重现

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Reproducibility of the Hybrid Capture 2 Test (HC 2) for human papillomavirus (HPV) DNA detection was evaluated by assaying frozen cervical specimens in 1997 and again in 2001 from 1,775 women with normal cervical cytology. Using a cutoff point of 1.0 pg of HPV DNA/ml between a negative and a positive test result, the result of the kappa test for agreement was 0.72 (a kappa value of >0.60 is considered good agreement). Using cutoff points of 1.0 and 10.0 pg/ml between negative and low positive and between low positive and high positive, respectively, the kappa was 0.68 and the linear-weighted kappa was 0.76. The results of this study indicate that HC 2 testing is reproducible even among cytologically normal women with low test values.
机译:通过在1997年和2001年再次从1775名宫颈细胞学正常的女性中检测冷冻的宫颈标本,评估了Hybrid Capture 2 Test(HC 2)对人乳头瘤病毒(HPV)DNA检测的可重复性。在阴性和阳性测试结果之间使用1.0 pg HPV DNA / ml的临界点,kappa一致性测试的结果为0.72(kappa值> 0.60被认为是良好的一致性)。在负值和低值正值之间以及低值正值和高值正值之间分别使用1.0和10.0 pg / ml的截止点,kappa为0.68,线性加权kappa为0.76。这项研究的结果表明,即使在细胞学正常的妇女中,HC 2检测值低,检测值也可重现。