Use of the VITEK 2 System for Rapid Identification of Clinical Isolates of Staphylococci from Bloodstream Infections

机译:使用VITEK 2系统快速鉴定来自血流感染的葡萄球菌临床分离株

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Staphylococci are an increasing cause of bloodstream infections. Rapid reliable identification of these organisms is essential for accurate diagnosis and prompt effective treatment. We evaluated the ability of the VITEK 2 system (bioMérieux, Inc, Hazelwood, Mo.) to identify these organisms rapidly and accurately. A total of 405 clinically relevant nonduplicate staphylococcal isolates (Staphylococcus aureus, n = 130; coagulase-negative staphylococci, n = 275) collected from blood cultures were tested. VITEK 2 results were considered correct when they were identical to those furnished by the comparison method based on the ID 32 STAPH system (bioMérieux, Marcy l'Etoile, France) plus supplementary manual testing. When discrepancies occurred, isolate identity was verified by molecular typing. The VITEK 2 correctly identified 387 (95.6%) isolates at the species level: 379 (including all but one [99.2%] of 130 S. aureus isolates and 249 of 275 [90.5%] coagulase-negative isolates) were identified by the automated reading; for the other eight, supplemental tests suggested by the manufacturer had to be used. Only one strain (0.2%) was misidentified (Staphylococcus hominis as Staphylococcus epidermidis), and four (1%), all S. epidermidis, were not identified. For the remaining 13 strains (including 10 S. hominis), the VITEK 2 system was unable to discriminate among two species, and no supplemental tests were suggested for conclusive identification. Over 90% of results were obtained within 4 h. These results suggest that the VITEK 2 system can provide rapid, accurate, and reliable species-level identification of staphylococci responsible for bloodstream infections, although there is room for improvement in the identification of certain coagulase-negative species, especially S. hominis.
机译:葡萄球菌是引起血流感染的原因。快速可靠地鉴定这些生物对于准确诊断和迅速有效治疗至关重要。我们评估了VITEK 2系统(bioMérieux,Inc,Hazelwood,密苏里州)快速准确地识别这些生物的能力。从血液中收集的共405种临床相关的非重复葡萄球菌分离株(金黄色葡萄球菌 n = 130;凝固酶阴性葡萄球菌, n = 275)文化进行了测试。如果VITEK 2结果与基于ID 32 STAPH系统(法国梅西市Marcy l'Etoile的bioMérieux)和补充手动测试的比较方法所提供的结果相同,则认为它们是正确的。当出现差异时,通过分子分型验证分离株的身份。 VITEK 2在物种水平上正确鉴定出387(95.6%)分离株:379(除130个金黄色葡萄球菌中的一个[99.2%]以外,其余全部和275(90.5%)凝固酶阴性的249个)。分离物)通过自动阅读识别;对于其他八种,必须使用制造商建议的补充测试。只有一个品系(0.2%)被误认为(人形葡萄球菌(Staphylococcus hominis)为表皮葡萄球菌(Staphylococcus epidermidis)),还有四个(1%)被误认为S。未发现表皮。对于其余的13个菌株(包括10个 S。hominis ),VITEK 2系统无法区分两个物种,因此没有建议进行补充试验来进行最终鉴定。在4小时内获得了90%以上的结果。这些结果表明,VITEK 2系统可以快速,准确和可靠地对造成血流感染的葡萄球菌进行物种级别的鉴定,尽管在某些凝固酶阴性物种(尤其是 S)的鉴定方面仍有改进的余地。原始人

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号