...
首页> 外文期刊>Journal of Clinical Microbiology >Efficiencies of Four Versions of the AMPLICOR HIV-1 MONITOR Test for Quantification of Different Subtypes of Human Immunodeficiency Virus Type 1
【24h】

Efficiencies of Four Versions of the AMPLICOR HIV-1 MONITOR Test for Quantification of Different Subtypes of Human Immunodeficiency Virus Type 1

机译:四个版本的AMPLICOR HIV-1 MONITOR测试用于量化1型人类免疫缺陷病毒不同亚型的效率

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Three versions of a commercial human immunodeficiency virus (HIV) type 1 (HIV-1) load test (the AMPLICOR HIV-1 MONITOR Test versions 1.0, 1.0+, and 1.5; Roche Diagnostics, Branchburg, N.J.) were evaluated for their ability to detect and quantify HIV-1 RNA of different genetic subtypes. Plasma samples from 96 patients infected with various subtypes of HIV-1 (55 patients infected with subtype A, 9 with subtype B, 21 with subtype C, 2 with subtype D, 7 with subtype E, and 2 with subtype G) and cultured virus from 29 HIV-1 reference strains (3 of subtype A, 6 of subtype B, 5 of subtype C, 3 of subtype D, 8 of subtype E, 3 of subtype F, and 1 of subtype G) were tested. Detection of subtypes A and E was significantly improved with versions 1.0+ and 1.5 compared to that with version 1.0, whereas detection of subtypes B, C, D, and G was equivalent with the three versions. Versions 1.0, 1.0+, and 1.5 detected 65, 98, and 100% of the subtype A-infected samples from patients, respectively, and 71, 100, and 100% of the subtype E-infected samples from patients, respectively. Version 1.5 yielded a significant increase in viral load for samples infected with subtypes A and E (greater than 1 log10 HIV RNA copies/ml). For samples infected with subtype B, C, and D and tested with version 1.5, only a slight increase in viral load was observed (<0.5 log10). We also evaluated a prototype automated version of the test that uses the same PCR primers as version 1.5. The results with the prototype automated test were highly correlated with those of the version 1.5 test for all subtypes, but were lower overall. The AMPLICOR HIV-1 MONITOR Test, version 1.5, yielded accurate measurement of the HIV load for all HIV-1 subtypes tested, which should allow the test to be used to assess disease prognosis and response to antiretroviral treatment in patients infected with a group M HIV-1 subtype.
机译:对三种版本的1型商业人类免疫缺陷病毒(HIV)负荷测试(AMPLICOR HIV-1 MONITOR测试版本1.0、1.0+和1.5; Roche Diagnostics,Branchburg,NJ)进行了评估,检测和量化不同遗传亚型的HIV-1 RNA。从96名感染了各种HIV-1亚型的患者(55位感染亚型,9位B型,21位C型,2位D型,7位E型和2位G型)的血浆样本中从29个HIV-1参考菌株(3个亚型A,6个亚型B,5个C型,3个D型,8个E型,3个F型和1个G型)进行了测试。与1.0版相比,使用1.0+和1.5版对A和E亚型的检测显着改善,而对B,C,D和G亚型的检测与这三个版本等效。版本1.0、1.0+和1.5分别检测到来自患者的65%,98%和100%的A型感染样本,以及分别来自患者的71%,100%和100%的E型感染的样本。对于感染亚型A和E的样本(大于1 log 10 HIV RNA拷贝/ ml),版本1.5显着增加了病毒载量。对于感染了B,C和D亚型并经1.5版测试的样品,仅观察到病毒载量略有增加(<0.5 log 10 )。我们还评估了该测试的原型自动化版本,该版本使用与1.5版相同的PCR引物。原型自动化测试的结果与所有亚型的1.5版测试的结果高度相关,但总体而言较低。 1.5版的AMPLICOR HIV-1 MONITOR测试(1.5版)可准确测量所有测试过的HIV-1亚型的HIV含量,这应可使该测试用于评估M组感染患者的疾病预后和对抗逆转录病毒治疗的反应HIV-1亚型。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号