The new resin-containing BACTEC 26 Plus blood culturing system (Becton Dickinson Diagnostic Instrument Systems, Towson, Md.) was compared with the Isolator 10 system (Wampole Laboratories, Cranbury, N.J.). Blood samples were drawn by syringe, and equal 10-ml volumes were evaluated in each blood culture system by the recommended methods. Both systems were incubated aerobically with 5% CO2. Of 11,506 acceptable study specimens, 1,788 aerobic isolates were recovered. Overall, recoveries was similar for the two systems, with 626 bacteria or fungi recovered in the BACTEC 26 Plus system only, 499 recovered in the Isolator system only, and 663 recovered in both systems. Of 345 gram-negative rods, 62 grew in the BACTEC system only and 109 grew in the Isolator system only (P less than 0.001). Thirty-three of these Isolator-only gram-negative organisms were Acinetobacter spp. Of 209 yeasts, 38 grew in BACTEC only and 81 grew in Isolator only (P less than 0.001). Of 200 streptococci and enterococci, 98 were recovered in BACTEC only and 26 grew in Isolator only (P less than 0.001). Two hundred twenty-eight independent episodes of gram-negative rod bacteremia occurred. Isolator was the first system positive in 59 of 197 episodes, compared with 45 of 197 for BACTEC when Acinetobacter episodes were excluded. Times to detection were similar for the two systems. High colony counts correlated with repeat positive blood cultures. Isolator and BACTEC had similar overall recoveries, with individual merits and deficiencies for both systems. The additional quantitative information derived from Isolator had utility in our institution.
机译:将新的含树脂的BACTEC 26 Plus血液培养系统(马里兰州Towson的Becton Dickinson诊断仪器系统)与Isolator 10系统(Wampole Laboratories,Cranbury,N.J。)进行了比较。通过注射器抽取血样,并通过推荐的方法在每个血液培养系统中评估等体积的10 ml。两种系统都用5%CO2进行有氧培养。在11,506个可接受的研究标本中,回收了1,788个有氧菌株。总体而言,两个系统的回收率相似,仅在BACTEC 26 Plus系统中回收了626种细菌或真菌,仅在隔离器系统中回收了499种细菌,在两个系统中回收了663种细菌或真菌。在345克负性棒中,仅BACTEC系统中生长62根,而隔离器系统中生长109根(P小于0.001)。这些仅隔离剂的革兰氏阴性菌中有33种是不动杆菌属。在209个酵母中,只有38个仅在BACTEC中生长,而81个仅在Isolator中生长(P小于0.001)。在200个链球菌和肠球菌中,仅在BACTEC中回收了98个,仅在隔离器中回收了26个(P小于0.001)。发生了228例革兰氏阴性杆状菌血症的独立发作。隔离剂是197次发作中第一个系统阳性,而排除不动杆菌发作的BACTEC则为197次发作中的45次。两个系统的检测时间相似。高菌落数与重复阳性血液培养有关。隔离器和BACTEC的总体回收率相似,两种系统各有优缺点。从隔离器获得的其他定量信息在我们的机构中​​有用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号