Evaluation of isolator system and large-volume centrifugation method for culturing body fluids.

机译:培养体液的隔离系统和大容量离心方法的评估。

获取原文
           

摘要

The Isolator system was compared with the large-volume centrifugation method for processing and recovering organisms from body fluids other than blood, cerebrospinal fluid, and urine. A total of 155 body fluid samples were processed for the recovery of clinically significant organisms. Of the 55 positive cultures, Isolator detected 94% and the large-volume centrifugation method detected 64%. The time necessary to indicate positivity was not significantly different in the two methods; however, in five cases, the Isolator system yielded clinically significant organisms 24 h sooner than the conventional method. The Isolator system was found to be a more sensitive alternative than the conventional large-volume centrifugation method.