首页> 外文期刊>Journal of Clinical Microbiology >Limited usefulness of quantitative culture of blood drawn through the device for diagnosis of intravascular-device-related bacteremia.
【24h】

Limited usefulness of quantitative culture of blood drawn through the device for diagnosis of intravascular-device-related bacteremia.

机译:通过该设备抽取的血液定量培养对诊断血管内设备相关菌血症的作用有限。

获取原文
   

获取外文期刊封面封底 >>

       

摘要

The use of a differential quantitative blood culture technique (Isolator) to diagnose intravascular-device-related bacteremia (IDRB) was studied prospectively. During septic episodes in 44 patients, blood was obtained simultaneously through the suspected infected device and from a peripheral venipuncture. The blood samples were processed by the Isolator technique, which enables easy quantification of microorganisms. The cannula was removed, and its tip was cultured semiquantitatively. Of the 52 cannulas studied, 15 were the cause of IDRB, but only 7 of these showed a significantly higher bacterial count in blood obtained through the device compared with peripheral blood. The bacterial count was higher in blood drawn through the device than in peripheral blood in four of six cases that did not fulfill the definition of IDRB. Some blood cultures obtained through the device were positive despite negative cultures of peripheral blood and cannula tips (six cannulas). Quantitative blood cultures were not useful in diagnosing IDRB in this study.
机译:前瞻性研究了使用差分定量血液培养技术(Isolator)诊断血管内装置相关菌血症(IDRB)的方法。在44名患者的败血病发作期间,通过疑似感染设备和外周静脉穿刺术同时获得了血液。血样通过隔离器技术处理,该技术能够轻松量化微生物。拔出套管,并对其尖端进行半定量培养。在研究的52个插管中,有15个是IDRB的病因,但与外周血相比,只有7个显示通过该设备获得的血液中细菌的数量显着增加。在不符合IDRB定义的6例病例中,有4例通过器械抽出的血液中细菌计数高于外周血。尽管外周血和插管尖端(六个插管)培养阴性,但通过该设备获得的一些血液培养仍为阳性。在这项研究中,定量的血液培养对诊断IDRB没有帮助。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号