首页> 外文期刊>Journal of Clinical Microbiology >Evaluation of the Quantum II yeast identification system.
【24h】

Evaluation of the Quantum II yeast identification system.

机译:量子II酵母鉴定系统的评估。

获取原文
           

摘要

We compared three methods for identifying clinical yeast isolates: Abbott Quantum II, API 20C, and a modified BBL Minitek system. The API 20C and modified Minitek systems agreed on the identification of 243 of 245 yeasts (99.2%). The Quantum II system correctly identified 197 (80.4%), incorrectly identified 19 (7.8%), and did not identify 29 (11.8%) of the yeasts. Most of the misidentifications with the Quantum II occurred because assimilation or biochemical results were false-positive. Sixteen different species of yeasts and 16 different Quantum II substrates contributed to the discrepancies. On retesting with the Quantum II, 31% of the discrepant strains were correctly identified, while the remaining 69% were incorrectly identified or were not identified. Erroneous biochemical and assimilation results were also noted with yeasts that were correctly identified by the Quantum II system.
机译:我们比较了三种鉴定临床酵母菌的方法:Abbott Quantum II,API 20C和改良的BBL Minitek系统。 API 20C和改良的Minitek系统同意鉴定245个酵母菌中的243个(99.2%)。 Quantum II系统正确地识别了197个(80.4%),错误地识别了19个(7.8%),并且没有识别出29个(11.8%)的酵母。大多数与Quantum II的错误识别是由于同化或生化结果为假阳性而发生的。十六种不同的酵母菌和16种不同的Quantum II底物造成了差异。在使用Quantum II重新测试时,正确识别出31%的差异菌株,而其余69%被正确识别或未识别。用Quantum II系统正确鉴定的酵母还指出了错误的生化和同化结果。