摘要

Four methods for the measurement of serum gentamicin concentration were evaluated with respect to cost-effectiveness, accuracy, and precision. Gentamicin concentration was determined in 112 clinical samples by the Staphlococcus epidermidis agar diffusion bioassay procedure in routine service in our laboratory at the time this study was initiated. Appropriate portions of these clinical samples were frozen and later thawed for remeasurement of gentamicin by bioassay or for measurement of gentamicin in one of three other systems. These included the Enzymatic Radiochemical Assay, the Diagnostic Products Corporation Radioimmunoassay and the New England Nuclear Corporation Radioimmunoassay. In addition, gentamicin dissolved in horse serum at 2, 4, 6, 8, 10, and 12 micrograms/ml was aliquoted, frozen, and later thawed for assay in each of the above systems. The data were analyzed for evidence of constant and proportional bias as well as for accuracy and precision.
机译:就成本效益,准确性和精密度,评估了四种测定血清庆大霉素浓度的方法。本研究开始时,在我们实验室的常规服务中,通过表皮葡萄球菌琼脂扩散生物测定方法确定了112种临床样品中的庆大霉素浓度。将这些临床样品的适当部分冷冻,然后融化,以通过生物测定法重新测定庆大霉素或在其他三个系统之一中测定庆大霉素。这些包括酶促放射化学测定,诊断产品公司放射免疫测定和新英格兰核公司放射免疫测定。另外,将等分于2、4、6、8、10和12微克/毫升的庆大霉素溶解在马血清中,冷冻,然后解冻以用于上述每个系统中的测定。对数据进行了分析,以获得恒定和比例偏差以及准确性和精确性的证据。