首页> 外文期刊>Journal of Clinical Microbiology >Comparison of Micro-ID, API 20E, and Conventional Media Systems in Identification of Enterobacteriaceae
【24h】

Comparison of Micro-ID, API 20E, and Conventional Media Systems in Identification of Enterobacteriaceae

机译:Micro-ID,API 20E和常规培养基系统在肠杆菌科鉴定中的比较

获取原文
           

摘要

The Micro-ID, a new identification kit for Enterobacteriaceae, consists of 15 biochemical tests, with substrates and reagents impregnated in filter paper disks. A 0.2-ml amount of an organism suspension equal to a 0.5 McFarland standard is pipetted into each of the compartments. After 4 h of incubation and addition of potassium-hydroxide (KOH) to the Voges-Proskauer test, the color reactions are read according to the recommendations of the manufacturer. A five-digit octal code number is derived from each set of reactions from which an identification is derived by using a code book. In a single-blind, comparative study of the Micro-ID system with the API 20E system (Analytab Products Inc.) and conventional biochemical tube media, we found that the Micro-ID and the API 20E systems gave a 90% identification correlation when each was compared with the conventional tube media. A comparison of all three systems gave an 82% overall identification correlation. When the common tests of Micro-ID and API 20E were compared with conventional tube media, we found that the tests in the Micro-ID performed as well as or better than those of the API 20E. Certain groups of organisms, i.e., Citrobacter, Enterobacter, Proteus, Salmonella, and Serratia genera, were found to give low correlation on certain common tests. When using primary isolation MacConkey plates from the clinical laboratory, only 74% of the plates with Enterobacteriaceae had sufficient numbers of colonies of each enteric organism to produce the 0.5 McFarland inoculum density required. Problems concerning the misidentification of some organisms are discussed.
机译:Micro-ID,一种用于肠杆菌科的新鉴定试剂盒,包括15个生化测试,底物和试剂浸在滤纸盘中。将0.2 ml等于0.5 McFarland标准的生物悬浮液吸移到每个隔室中。孵育4小时并向Voges-Proskauer测试中添加氢氧化钾(KOH)后,根据制造商的建议读取显色反应。从每组反应中得出一个五位数字的八进制代码,使用代码本从中得出标识。在与API 20E系统(Analytab Products Inc.)和常规生化管介质进行的Micro-ID系统的单盲比较研究中,我们发现Micro-ID和API 20E系统在鉴定时具有90%的识别相关性每种都与常规管介质进行了比较。所有三个系统的比较给出了82%的整体识别相关性。当将Micro-ID和API 20E的常规测试与常规试管介质进行比较时,我们发现Micro-ID中的测试表现优于或优于API 20E。在某些常见测试中,发现某些种类的生物,即柠檬酸杆菌,肠杆菌,变形杆菌,沙门氏菌和沙雷氏菌属,其相关性较低。当使用临床实验室的初次分离MacConkey平板时,只有74%的带有 Enterobacteriaceae 的平板具有足够数量的每种肠道生物菌落,以产生所需的0.5 McFarland接种密度。讨论了与某些生物的误识别有关的问题。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号