首页> 外文期刊>Journal of Clinical Microbiology >New method for concentration and quantitation of Mycobacterium leprae.
【24h】

New method for concentration and quantitation of Mycobacterium leprae.

机译:浓缩和定量麻风分枝杆菌的新方法。

获取原文
           

摘要

A new method of enumerating Mycobacterium leprae has been developed. Suspensions containing the organisms were filtered through a polycarbonate membrane filter (25-mm diameter, 0.4-micronm pore size, 10-micronm thick; Nucleopore) to concentrate the organisms. The membrane was then mounted on a glass slide and stained with a standard acid-fast stain. Finally, the membrane was treated with a small amount of chloroform to fix it to the slide and make it transparent. This method enabled us to detect M. leprae in quantities as small as 4.98 X 10(2) regardless of the total volume of the original material. Comparison with a standard method for enumerating M. leprae showed that both methods gave similar results when the organisms counted by the standard method were present in sufficient quantity for reproducibility. Because the least number of organisms that can be detected with the standard method is 10(4) ml and because the organisms detected with the new method could be concentrated on the polycarbonate filter from a large amount of infected fluid, a substantial number of suspensions were shown by the new method, but not by the standard method, to contain M. leprae.
机译:已经开发了一种计数麻风分枝杆菌的新方法。通过聚碳酸酯膜滤器(直径25毫米,孔径0.4微米,厚10微米;核孔)过滤含有生物的悬浮液,以浓缩生物。然后将膜安装在载玻片上,并用标准耐酸染料染色。最后,用少量氯仿处理膜,将其固定在玻片上并使之透明。这种方法使我们能够检测到麻风支原体的数量小至4.98 X 10(2),而不论原始材料的总体积如何。与标准方法进行麻风分枝杆菌计数的比较表明,当通过标准方法计数的生物体具有足够的可再现性时,两种方法都得出相似的结果。由于使用标准方法可以检测到的生物最少,为10(4)ml,并且由于使用新方法检测到的生物可以从大量感染液中浓缩到聚碳酸酯滤膜上,因此产生了大量的悬浮液。用新方法(但不是标准方法)显示含有麻风杆菌。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号