首页> 外文期刊>Journal of Clinical Microbiology >Rapid isolation and presumptive diagnosis of uropathogens by using membrane filtration and differential media.
【24h】

Rapid isolation and presumptive diagnosis of uropathogens by using membrane filtration and differential media.

机译:通过使用膜过滤和差异介质快速分离并推测性诊断尿路致病菌。

获取原文
           

摘要

Random urine samples from hospitalized patients (n = 550) and seeded sterile filtered urine samples (n = 730) were used to test a membrane filtration technique, Qualture (Future Medical Technologies International, Inc., West Palm Beach, Fla.), for the detection and identification of uropathogens. Results for each sample were compared with those obtained by the calibrated loop (0.01 ml) method to demonstrate the sensitivity of the method as a screening tool and the specificity of the presumptive diagnosis obtained from the pattern of growth on differential media. The medium was supplied as dehydrated nutrient pads (Sartorius AG, Goettingen, Germany) and was activated by rehydration by the addition of the liquid specimen. With a threshold of 10(4) CFU/ml defining a positive culture, the sensitivity of the Qualture was 100%. At lower levels of bacteriuria, the Qualture was more sensitive than the calibrated loop method. Significant infections were presumptively diagnosed at 4 h by filtration rather than at 24 h on agar medium. The specificity of uropathogen identification ranged from 99% for Enterococcus spp. to 83% for Pseudomonas spp. Citrobacter spp. could not be differentiated from Escherichia coli and Providencia spp. could not be differentiated from Proteus spp., which does not create a therapeutic dilemma. Filtration, isolation, quantitation, and presumptive diagnosis are performed in one step, without subculture. Membrane filtration is a sensitive and rapid technique, with the advantage that it can be used as a collection and transport device without the use of growth inhibitors.
机译:使用住院患者的随机尿液样本(n = 550)和接种无菌过滤尿液样本(n = 730)来测试膜过滤技术Qualture(Future Medical Technologies International,Inc.,West Palm Beach,FL)。尿毒症的检测和鉴定。将每个样品的结果与通过校正定量环(0.01 ml)方法获得的结果进行比较,以证明该方法作为筛选工具的敏感性以及从差异培养基上的生长方式获得的推定诊断的特异性。该培养基以脱水的营养垫(德国萨特里乌斯公司,哥廷根,德国)的形式提供,并通过添加液体样本进行再水化而活化。以10(4)CFU / ml的阈值定义阳性培养时,Qualture的灵敏度为100%。在较低的细菌尿水平下,Qualture比校准定量环方法更灵敏。据推测,在过滤后4小时而非在琼脂培养基上24小时即可诊断出明显的感染。尿病原菌鉴定的特异性对肠球菌的鉴定范围为99%。假单胞菌占83%。柠檬杆菌属不能与大肠杆菌和普罗维登西亚菌种区分开。不能与Proteus spp。区别开来,Proteus spp。不会造成治疗难题。过滤,分离,定量和推测性诊断只需一步即可完成,无需传代培养。膜过滤是一种灵敏且快速的技术,其优点是可以在不使用生长抑制剂的情况下用作收集和运输设备。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号