The reverse-flow apparatus is a new device for enhancing the detection of bacteria in urine. Bacteria are trapped onto a customized filter, and the pigments, crystals, and other interfering substances in the urine pass through the filter and are discarded. The bacteria are backflushed and are recovered as a concentrate, and the concentrate is then processed through the previously described colorimetric bacteriuria detection device. A total of 1,000 urine samples were obtained from randomly selected patients and were cultured on agar. Upon enumeration of the colonies, 160 urine samples were shown to contain more than 10(5) CFU/ml. In the bacteriuria detection device, 150 urine samples could not be processed (pigmenters and cloggers), and of the 850 urine samples processed, 127 were culture positive for 10(5) CFU/ml or greater, and 150 urine samples contained between 10(4) and 10(5) CFU/ml. At 10(5) CFU/ml, there were 140 false-positives and 14 false-negatives. When duplicate urine samples were processed through and concentrated by our new reverse-flow apparatus, all samples, including the above pigmenters and cloggers, could be tested in the bacteriuria detection device. The 150 unprocessable samples described above yielded 33 additional bacteria-positive urines, 23 at the 10(5)-CFU/ml cutoff and 10 at the 10(4)-to-10(5)-CFU/ml cutoff. There were 105 false-positives at 10(5) CFU/ml and only 2 false-negatives at the same level of bacteria. At 10(4) to 10(5) CFU/ml there was only 1% false-positive and 4% false-negative. The reverse-flow apparatus allows greater specificity and sensitivity in the rapid bacteriuria test. Urine containing 10(4) CFU/ml or more can now be detected with a 96% sensitivity in a total processing time of less than 2 min.
机译:逆流装置是用于增强对尿液中细菌的检测的新装置。细菌被截留在定制的过滤器上,尿液中的色素,晶体和其他干扰物质通过过滤器并被丢弃。细菌被反冲并作为浓缩物被回收,然后浓缩物通过前述比色细菌检测设备进行处理。从随机选择的患者中获得总共1,000个尿液样本,并在琼脂上进行培养。在对菌落进行计数时,显示160个尿液样本中含有超过10(5)CFU / ml。在菌尿检测设备中,无法处理150个尿液样本(色素沉着剂和记录器),在处理的850个尿液样本中,有127个培养物中的10(5)CFU / ml或更高呈阳性,而150个尿液样本中的10(5)CFU / ml 4)和10(5)CFU / ml。在10(5)CFU / ml下,有140个假阳性和14个假阴性。当重复的尿液样本通过我们的新型逆流设备进行处理并浓缩时,所有样本,包括上述色素沉着器和记录器都可以在细菌检测设备中进行测试。上述150个无法处理的样品产生了33个额外的细菌阳性尿液,其中10(5)-CFU / ml临界值为23,而10(4)-10(5)-CFU / ml临界值为10。在10(5)CFU / ml下有105个假阳性,而在相同细菌水平下只有2个假阴性。在10(4)至10(5)CFU / ml下,只有1%的假阳性和4%的假阴性。逆流设备在快速细菌尿液测试中具有更高的特异性和灵敏度。现在可以在少于2分钟的总处理时间内以96%的灵敏度检测出尿液中含有10(4)CFU / ml或更高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号