Automated reading of MIC microdilution trays containing fluorogenic enzyme substrates with the Sensititre Autoreader.

机译:使用Sensititre Autoreader自动读取含有荧光酶底物的MIC微量稀释托盘。

获取原文
           

摘要

The Sensititre Autoreader is a microcomputer-driven instrument capable of automatically reading antimicrobial susceptibility microdilution trays. The instrument measures the fluorescence liberated by bacterial enzymatic activity on fluorogenic substrates as an indicator of growth in each well. A mathematical algorithm converts the fluorescent signals from an antimicrobial dilution series to an MIC endpoint. A three-center study evaluated the performance of the Autoreader in comparison with MIC determined visually in a duplicate set of control plates lacking fluorogenic substrate. Among 828 isolates of gram-negative bacilli tested against 17 antimicrobial agents, Autoreader 18-h MIC were within +/- 1 twofold dilution of control MIC values (agreement) in 95.3% of instances. In 3.5% of the instances, Autoreader values occurred +/- 2 half-step dilutions from control values (minor discrepancy), and in only 1.2% of instances did Autoreader values deviate from control values by greater than +/- 2 dilution steps (major discrepancy). Agreement, minor discrepancies, and major discrepancies were noted among 148 gram-positive cocci tested against 11 antimicrobial agents in 93.5, 4.8, and 1.7% of the instances, respectively. Over half of the major discrepancies noted with gram-negative bacilli occurred with Proteus mirabilis-beta-lactam combinations, a problem that was resolved when a lower initial inoculum was used. Inter-and intralaboratory reproducibility was excellent. Standard Sensititre susceptibility trays may be instrument read at 18 h reproducibly and accurately with only slight modification of conventional procedures to include fluorogenic enzyme substrates in the incubation broth.
机译:Sensititre Autoreader是一款由微机驱动的仪器,能够自动读取抗菌药物敏感性微量稀释托盘。该仪器测量由细菌酶活性在荧光底物上释放的荧光,作为每个孔中生长的指标。数学算法可将荧光信号从抗菌素稀释系列转换为MIC终点。一项三中心研究评估了自动阅读器的性能,并将其与在无荧光底物的重复对照板组中目测确定的MIC进行了比较。在针对17种抗微生物剂测试的828株革兰氏阴性菌中,Autoreader 18-h MIC在95.3%的情况下相对于对照MIC值(协议)在+/- 1倍稀释度之内。在3.5%的实例中,自动读数器值与对照值发生+/- 2个半步稀释(轻微差异),只有1.2%的实例中自动读数器值与对照值的偏差大于+/- 2个稀释步长(重大差异)。在分别针对93.5、4.8和1.7%的实例针对11种抗菌药物进行测试的148克阳性球菌中,发现一致性,轻微差异和重大差异。革兰氏阴性杆菌引起的主要差异中有一半以上是由奇异变形杆菌-β-内酰胺组合引起的,使用较低的初始接种量后该问题得以解决。实验室间和实验室内的重复性极好。标准Sensititre药敏性药盘可在18 h重复性和准确地读取仪器,只需对常规程序稍作改动即可将荧光酶底物包括在培养液中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号