...
首页> 外文期刊>Journal of Clinical Microbiology >Detection of Entamoeba histolytica immunoglobulins G and M to plasma membrane antigen by enzyme-linked immunosorbent assay.
【24h】

Detection of Entamoeba histolytica immunoglobulins G and M to plasma membrane antigen by enzyme-linked immunosorbent assay.

机译:通过酶联免疫吸附测定法检测溶质变形虫肠球菌免疫球蛋白G和M对质膜抗原的检测。

获取原文
           

摘要

Sixty-one serum specimens from 22 patients with clinically diagnosed amoebic liver abscess (ALA), 10 hospitalized patients with a variety of diseases other than amoebiasis, 12 normal healthy controls, and 17 subjects from an amoebiasis-endemic area were assayed by enzyme-linked immunosorbent assay (ELISA). The plasma membrane fraction of axenic cultures of Entamoeba histolytica HK9 separated from other subcellular fractions by differential centrifugation was used as the antigen to detect specific immunoglobulin G (IgG) and IgM antibodies. Using a single serum dilution of 1/100 and optical densities at 492 nm of 0.200 and 0.250 as the cutoff values for the IgM and IgG ELISAs, their respective sensitivities in 22 ALA patients were 91% (20 of 22) and 95% (21 of 22). In 22 patients (10 hospitalized and 12 normal healthy controls), the specificities of the IgM and IgG ELISAs were 95% (21 of 22) and 91% (20 of 22), respectively. All five asymptomatic carriers of pathogenic E. histolytica were seropositive by the IgG ELISA and the amoebic gel diffusion test (AGDT). The AGDT was positive for three of six culture-negative controls, while the IgG ELISA was positive for all six. For six asymptomatic carriers of nonpathogenic zymodemes, the AGDT was positive for two, and the IgG ELISA was positive for three. There was an excellent correlation (r = 0.96) between the IgG ELISA and the AGDT. Only one of six culture-negative controls, none of the asymptomatic carriers of pathogenic E. histolytica, and one of six carriers of nonpathogenic E. histolytica were seropositive by the IgM ELISA, thus highlighting the specificity of the IgM ELISA in the diagnosis of ALA. It is believed that the use of plasma membrane fractions has improved the diagnostic potential of the IgM ELISA.
机译:通过酶联法检测了22例临床诊断为阿米巴肝脓肿(ALA)的患者,10例除阿米巴病以外的各种疾病的住院患者,12例正常健康对照以及来自阿米巴病流行地区的17名受试者的61份血清标本免疫吸附测定(ELISA)。通过差速离心从其他亚细胞级分中分离出的溶组织性变形虫阿米巴HK9的轴突培养物的质膜级分用作抗原,以检测特异性免疫球蛋白G(IgG)和IgM抗体。使用1/100的单一血清稀释液和492 nm处的光密度为0.200和0.250作为IgM和IgG ELISA的临界值,在22位ALA患者中它们各自的敏感性分别为91%(22个中的20个)和95%(21个) 22)。在22位患者(10位住院患者和12位正常健康对照)中,IgM和IgG ELISA的特异性分别为95%(22的21)和91%(20的22)。通过IgG ELISA和阿米巴凝胶扩散测试(AGDT),所有5种无症状的致病性大肠杆菌均呈阳性。 AGDT对六个培养阴性对照中的三个阴性,而IgG ELISA对所有六个阴性。对于六个无病原体的无症状携带者,AGDT阳性两个,而IgG ELISA阳性三个。 IgG ELISA和AGDT之间存在极好的相关性(r = 0.96)。通过IgM ELISA,只有六种培养阴性对照中的一种,无病原性大肠杆菌的无症状携带者和无病原性大肠杆菌的六种携带者之一呈血清反应阳性,因此突出了IgM ELISA在诊断ALA中的特异性。据信质膜级分的使用提高了IgM ELISA的诊断潜力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号