A total of 180 selected strains of gram-negative bacilli were tested for susceptibility to nine antibiotics by the prototype General Susceptibility Card and reference broth microdilution MIC method, and 112 of 180 were tested by the modified Gram-Negative General Susceptibility-Plus Card (Vitek Systems, Inc., Hazelwood, Mo.). When category calls--susceptible, intermediate, and resistant for the prototype card and very susceptible, moderately susceptible, and resistant for the modified card--were identical or compatible (very susceptible by one method and moderately susceptible by the other), the methods were considered in qualitative or categorical agreement. The overall categorical agreement improved from 83% for the prototype card to 91.5% for the modified card, and the frequency of major and very major disagreements was reduced from 7.5 to 1%, respectively. Overall agreement between the modified card and reference method for both category calls and MICs (+/- 2 dilutions) was 90%. Of the results, 67% were identical, 22% were more susceptible with the modified card, and 11% were more resistant. Reproducibility of identical or compatible category calls and MICs obtained from three trials was 94.5%. The poorest accuracy and reproducibility were observed when testing Pseudomonas aeruginosa. The study suggests that the modified card can rapidly and efficiently perform susceptibility tests with an acceptable level of accuracy and reproducibility provided that the system is appropriately used for testing strains of the family Enterobacteriaceae with preset criteria for excluding organism-antibiotic combinations. The evaluation also indicates dramatic improvement in the technical performance of the modified card compared with its earlier prototype.
机译:通过原型通用药敏卡和参考肉汤微稀释MIC方法测试了180株选定的革兰氏阴性菌对9种抗生素的敏感性,并使用改良的革兰氏阴性菌通用药敏卡(Vitek)测试了180株中的112株Systems,Inc.,Hazelwood,MO。)。当类别调用-对原型卡敏感,对中间和耐抗性,对易感性卡,中度敏感和对修改后的卡具有抗性时-是相同或兼容的(非常容易受一种方法的影响,而对另一种方法则是中度敏感的)被认为是定性或绝对一致的。总体类别一致性从原型卡的83%提高到了修改后的卡的91.5%,主要和非常不同意见的发生率分别从7.5%减少到1%。对于类别呼叫和MIC(+/- 2稀释),修改后的卡和参考方法之间的总体一致性为90%。在结果中,有67%的人是相同的,有22%的人更容易受到修改后的卡片的伤害,而11%的人则更有抵抗力。从三个试验中获得的相同或兼容类别呼叫和MIC的重现性为94.5%。测试铜绿假单胞菌时观察到最差的准确性和可重复性。这项研究表明,如果该系统适用于以排除微生物-抗生素组合的预设标准测试肠杆菌科菌株,则该修饰卡可以以可接受的准确度和可重复性水平快速有效地进行药敏试验。评估还表明,与早期的原型相比,改进后的卡的技术性能有了显着提高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号