Two rapid automated methods, the Syva EMIT Autolab 6000 (Syva Corp., Syntex Diagnostics, Ottawa, Ontario, Canada) and the Abbott TDX (Abbott Diagnostics, Mississauga, Ontario, Canada) systems, for determining amikacin, gentamicin and tobramycin levels in serum were evaluated for accuracy, reproducibility, and cost. Both methods had a high degree of accuracy and reproducibility in assaying gentamicin, amikacin, and tobramycin. The Abbott TDX required an average of only 1 min and 43 s for a single assay compared with 4 min and 15 s for the Syva EMIT automated system. Excluding the capital cost of equipment, the cost per assay by the Abbott TDX was +3.55 Canadian compared with +3.00 Canadian with the Syva EMIT automated system. Both systems performed well during this evaluation in a general diagnostic laboratory, but the Syva EMIT required more daily maintenance than the Abbott TDX system.
机译:两种快速自动化方法,即Syva EMIT Autolab 6000(Syva Corp.,Syntex Diagnostics,加拿大渥太华,加拿大)和Abbott TDX(Abbott Diagnostics,密西沙加,加拿大安大略省)系统,用于确定血清中的丁胺卡那霉素,庆大霉素和妥布霉素水平对准确性,可重复性和成本进行了评估。两种方法在测定庆大霉素,阿米卡星和妥布霉素时均具有高度的准确性和可重复性。雅培TDX一次分析平均只需要1分钟和43秒,而Syva EMIT自动化系统则需要4分钟和15秒。除去设备的资本成本,雅培TDX的每次测定成本为+3.55加拿大元,而使用Syva EMIT自动化系统的成本为+3.00加拿大元。在一般诊断实验室的评估过程中,两种系统均表现良好,但是Syva EMIT的日常维护工作比Abbott TDX系统更多。