The accuracies of the MicroScan Pos ID and Rapid Pos ID panel systems (Baxter Diagnostic Inc., MicroScan Division, West Sacramento, Calif.) were compared with each other and with the accuracies of conventional methods for the identification of 25 Staphylococcus species and 4 subspecies. Conventional methods included those used in the original descriptions of species and subspecies and DNA-DNA hybridization. The Pos ID panel uses a battery of 18 tests, and the Rapid Pos ID panel uses a battery of 42 tests for the identification of Staphylococcus species. The Pos ID panel has modified conventional and chromogenic tests that can be read after 15 to 48 h of incubation; the Rapid Pos ID panel has tests that use fluorogenic substrates or fluorometric indicators, and test results can be read after 2 h of incubation in the autoSCAN-W/A. Results indicated that both MicroScan systems had a high degree of congruence (greater than or equal to 90%) with conventional methods for the species S. capitis, S. aureus, S. auricularis, S. saprophyticus, S. cohnii, S. arlettae, S. carnosus, S. lentus, and S. sciuri and, in particular, the subspecies S. capitis subsp. capitis and S. cohnii subsp. cohnii. The Rapid Pos ID panel system also had greater than or equal to 90% congruence with conventional methods for S. epidermidis, S. caprae, S. warneri subsp. 2, S. xylosus, S. kloosii, and S. caseolyticus. For both MicroScan systems, congruence with conventional methods was 80 to 90% for S. haemolyticus subsp. 1, S. equorum, S. intermedius, and S. hyicus; and in addition, with the Rapid Pos ID panel system congruence was 80 to 89% for S. capitis subsp. ureolyticus, S. warneri subsp. 1, S. hominis, S. cohnii subsp. urealyticum, and S. simulans. The MicroScan systems identified a lower percentage (50 to 75%) of strains of S. lugdunensis, S. gallinarum, S. schleiferi, and S. chromogenes, although the addition of specific tests to the systems might increase the accuracy of identification significantly.
机译:比较了MicroScan Pos ID和Rapid Pos ID面板系统(Baxter Diagnostic Inc.,MicroScan Division,加利福尼亚州西萨克拉门托)的准确性,并与用于鉴定25个葡萄球菌和4个亚种的常规方法的准确性进行了比较。 。常规方法包括用于物种和亚种的原始描述以及DNA-DNA杂交的方法。 Pos ID面板使用18种测试电池,Rapid Pos ID面板使用42种测试电池来鉴定葡萄球菌种类。 Pos ID面板修改了常规和生色测试,可在孵育15至48小时后读取; Rapid Pos ID面板的测试使用了荧光底物或荧光指示剂,在autoSCAN-W / A中孵育2小时后即可读取测试结果。结果表明,两种MicroScan系统均与常规方法高度一致(大于或等于90%),该常规方法适用于头孢葡萄球菌,金黄色葡萄球菌,金黄色葡萄球菌,腐生葡萄球菌,co.ii葡萄球菌和拟南芥葡萄球菌,S。carnosus,S。lentus和S. sciuri,尤其是亚种S. capitis subsp.。 Capitis和S. cohnii亚种科尼Rapid Pos ID面板系统与表皮葡萄球菌,卡普拉葡萄球菌,华氏葡萄球菌亚种的常规方法的一致性也大于或等于90%。 2,木糖链球菌,克氏链球菌和干酪解链球菌。对于两个MicroScan系统,溶血链球菌亚种与常规方法的一致性为80%至90%。 1,equequum,S。intermedius和hyicus;另外,使用Rapid Pos ID面板系统,对卡介苗亚种的一致性为80%至89%。 ureolyticus,华氏链球菌亚种。 1,S. hominis,S. cohnii子亚种。解脲酶和S. simulans。尽管向系统中添加特定测试可能会显着提高鉴定的准确性,但MicroScan系统鉴定出的葡萄球菌,鸡链霉菌,schleiferi和产色链球菌的菌株所占比例较低(50%至75%)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号