The Antimicrobial Removal Device (ARD; Marion Scientific) was evaluated in vitro with simulated blood culture samples in fresh blood and clinically with samples from potentially septic patients to test its ability to remove antimicrobial agents and recover bacteria from blood culture specimens containing these drugs. In simulated specimens, the ARD was evaluated for adverse affects on microorganisms as well as compared with lysis-centrifugation (Isolator; Du Pont Co.), biphasic brain heart infusion bottles, and tryptic soy broth bottles for antimicrobial inactivation and organism recovery. There was no adverse effect of the ARD on organisms during a 4-h test period. The ARD was the only system to actually inactivate antimicrobial agents and removed greater than 99.2% of all antimicrobial agents tested from spiked and clinical specimens. Overall, with simulated blood culture specimens, the ARD recovered 90% of bacteria spiked into fresh blood containing antimicrobial agents, Isolator recovered 73%, biphasic brain heart infusion bottles recovered 31%, and tryptic soy broth bottles recovered 24%. In the clinical study, 43 of 86 clinically significant isolates were recovered only by ARD-assisted processing, 6 were recovered only by conventional processing, and 37 were recovered by both methods (the advantage of ARD processing over conventional processing in the clinical study was significant at P less than 0.001). Both clinical and simulated specimens demonstrated the ARD-associated blood culture processing to be the most efficient method for the isolation of microorganisms from specimens containing antimicrobial agents.
机译:用新鲜血液中的模拟血液培养样品体外评估了抗菌去除设备(ARD; Marion Scientific),临床上使用潜在败血症患者的样品对抗菌去除设备进行了评估,以测试其去除抗菌剂和从含有这些药物的血液培养样品中回收细菌的能力。在模拟标本中,评估了ARD对微生物的不利影响,并与裂解离心(Isolator; Du Pont Co.),双相脑心脏输液瓶和胰蛋白酶大豆肉汤瓶进行了抗微生物灭活和生物恢复的比较。在4小时的测试期间,ARD对生物体无不利影响。 ARD是唯一使抗菌剂真正失活的系统,并且从加标样本和临床样本中去除的所有抗菌剂中,其去除率均超过99.2%。总体而言,使用模拟的血液培养标本,ARD回收了掺入含有抗菌剂的新鲜血液中的90%细菌,隔离剂回收了73%,双相脑心脏输液瓶回收了31%,胰蛋白酶大豆肉汤瓶回收了24%。在临床研究中,仅通过ARD辅助处理回收了86个临床上重要的分离株中的43个,仅通过常规处理回收了6个,并且通过两种方法均回收了37个(在临床研究中ARD处理相对于常规处理的优势非常明显在P小于0.001)。临床和模拟标本都证明,与ARD相关的血液培养过程是从含抗菌剂标本中分离微生物的最有效方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号