首页> 外文期刊>Journal of Clinical Microbiology >Sensitive solid-phase radioimmunoassay for detection of human immunoglobulin G antibodies to varicella-zoster virus.
【24h】

Sensitive solid-phase radioimmunoassay for detection of human immunoglobulin G antibodies to varicella-zoster virus.

机译:用于检测水痘带状疱疹病毒的人免疫球蛋白G抗体的灵敏固相放射免疫分析。

获取原文
           

摘要

A sensitive solid-phase radioimmunoassay for detection of antibodies to varicella-zoster virus (VZV) is described. The antigen consisted of a sonically disrupted extract of VZV-infected human embryo cells. 125I-labeled rabbit anti-human immunoglobulin G (IgG) specific for the Fc portion of human IgG was used to detect human IgG bound to viral antigen. With this technique, 193 human sera were evaluated for their IgG antibody titer against ZVZ. Subjects included 62 healthy adults, 33 young children (12 healthy), and 49 patients. Titers obtained by the radioimmunoassay were compared with those obtained by indirect fluoresence antibody staining of membrane antigen. The radioimmunoassay technique described gave titers approximately 5 X 10(4) times higher than those shown by indirect fluorescence. It can be used for routine diagnosis, but is especially suited to determining immune status to VZV, as defined by presence or absence of antibodies to the virus; for epidemiological studies; or for determining patients at risk who are exposed to the virus. No heterotypic titer rises to VZV were observed in sera with fourfold or greater rises to Epstein-Barr virus or cytomegalovirus. Sera of eight subjects with fourfold or greater titer rises to herpes simplex virus reacted in various ways: in six cases no significant change occurred in titer to VZV; one had a significant decrease in titer by the radioimmunoassay; and one had a significant increase. Possible reasons for these titer changes are discussed.
机译:描述了用于检测水痘带状疱疹病毒(VZV)抗体的灵敏固相放射免疫测定。抗原由被VZV感染的人类胚胎细胞的经超声波破坏的提取物组成。对人IgG Fc部分特异的125I标记的兔抗人免疫球蛋白G(IgG)用于检测与病毒抗原结合的人IgG。使用该技术,评估了193个人血清针对ZVZ的IgG抗体效价。受试者包括62位健康的成年人,33位幼儿(12位健康)和49位患者。将通过放射免疫测定获得的滴度与通过膜抗原间接荧光抗体染色获得的滴度进行比较。所描述的放射免疫测定技术的滴度比间接荧光显示的滴度高约5 X 10(4)倍。它可以用于常规诊断,但特别适合于确定是否存在针对VZV的免疫状态,这取决于是否存在针对病毒的抗体;用于流行病学研究;或用于确定暴露于病毒的高危患者。在血清中未观察到异型滴度升高至VZV,而爱泼斯坦-巴尔病毒或巨细胞病毒升高四倍或更高。具有八倍或更高滴度的八名受试者的血清对单纯疱疹病毒的反应以多种方式发生:在六种情况下,对VZV的滴度没有显着变化;一种通过放射免疫测定的滴度显着降低;并有一个显着增加。讨论了这些滴度变化的可能原因。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号