An improved bioluminescent assay of gentamicin in serum, based on the dose-dependent effect of the agent on the accumulation of extracellular ATP in Escherichia coli LU 14 cultures, is presented. The accuracy of the bioluminescent assay of gentamicin, expressed as the mean coefficient of variation over the therapeutic range, was 2.8%. Corresponding figures for an agar diffusion assay, a latex agglutination inhibition card test, an enzyme immunoassay, and a fluorescence immunoassay were 6.4, 17.5, 4.2, and 9.4%, respectively. All of the methods correlated well (r = 0.926 to 0.976), with the possible exception of the card test (r = 0.777 to 0.841). The bioluminescent assay requires only 1 microliter of serum, which allows for capillary sampling, and results are available within 75 min.
机译:提出了一种改进的血清中庆大霉素生物发光分析方法,该方法基于试剂对大肠杆菌LU 14培养物中细胞外ATP积累的剂量依赖性作用。庆大霉素的生物发光测定的准确性(表示为治疗范围内的平均变异系数)为2.8%。琼脂扩散测定,乳胶凝集抑制卡试验,酶免疫测定和荧光免疫测定的相应数字分别为6.4%,17.5%,4.2%和9.4%。除卡测试(r = 0.777至0.841)外,所有方法的相关性都很好(r = 0.926至0.976)。生物发光测定法仅需1微升血清即可进行毛细管采样,结果可在75分钟内获得。