首页> 外文期刊>Journal of Clinical Microbiology >Comparison of lysis-centrifugation with a biphasic blood culture medium for the recovery of aerobic and facultatively anaerobic bacteria.
【24h】

Comparison of lysis-centrifugation with a biphasic blood culture medium for the recovery of aerobic and facultatively anaerobic bacteria.

机译:用双相血液培养基裂解-离心回收有氧和兼性厌氧细菌的比较。

获取原文
           

摘要

The Du Pont Isolator tube and Roche Septi-Chek blood culture bottle employ solid media which facilitate the removal of bacteria from static or cidal substances in blood to increase recovery and decrease detection time. In a comparison of 11,567 blood culture sets, the Isolator tube and vented Roche Septi-Chek bottle were positive for 533 (80%) and 494 (74%) of the aerobic and facultatively anaerobic organisms recovered, respectively. This difference was not significant. A significant difference was found in the overall detection time. The Isolator tube recovered the bacteria ca. 1 day earlier. The earlier detection time was most notable with Staphylococcus aureus, viridans streptococci, and Pseudomonas aeruginosa. Among the 355 bacteremic episodes analyzed by a computer program, the Isolator tube was responsible more often for the first report of bacteremia in a given patient. Both systems performed well for the recovery of aerobic and facultatively anaerobic bacteria, but it is recommended that either be used in combination with an unvented broth-containing bottle.
机译:杜邦隔离管和罗氏Septi-Chek血液培养瓶采用固体培养基,可从血液中的静态或杀灭性物质中去除细菌,从而提高回收率并缩短检测时间。在比较11567个血液培养集时,隔离管和Roche Septi-Chek通风瓶分别回收了533(80%)和494(74%)有氧和兼性厌氧生物阳性。这种差异并不明显。在总检测时间上发现了显着差异。隔离管回收细菌约。 1天前。金黄色葡萄球菌,绿脓杆菌链球菌和铜绿假单胞菌的检测时间最早。在通过计算机程序分析的355次细菌性发作中,隔离管是导致特定患者中菌血症首次报告的原因。两种系统在需氧和兼性厌氧菌的回收方面均表现良好,但建议将其与未通风的含肉汤瓶配合使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号