We evaluated the use of inocula prepared directly from blood agar plates in agar dilution susceptibility tests of anaerobic bacteria and compared the results with susceptibility results obtained from the National Committee for Clinical Laboratory Standards proposed thioglycolate broth cultures. The objectives were to evaluate the reproducibility of each of the two methods of inoculum preparation and to compare the MICs obtained by each method. The reproducibility studies were conducted on 14 stock strains. The mode MICs obtained by the direct agar method were identical to those obtained by the reference broth method 74% of the time and within +/- 1 log2 dilution 100% of the time. The degree of reproducibility of each of the two methods was identical (93% +/- 1 log2 dilution). MIC results obtained by the direct agar method agreed with the MICs obtained by the reference broth culture method in 92.9% of 1,125 MIC data pair determinations performed on stock cultures. The reproducibility of the direct agar method within +/- 1 log2 dilution step for 115 fresh clinical isolates was 93%, including 93.4% of the results with the Bacteroides fragilis group. Only two very major discrepancies (false-susceptible by the agar method) were identified among the 708 MIC data pairs on these clinical isolates. Preparation of inocula directly from growth on agar plates provides a rapid and reproducible method for agar dilution susceptibility testing of anaerobes.
机译:我们评估了直接从血琼脂平板制备的接种物在厌氧菌琼脂稀释药敏试验中的使用,并将结果与​​从美国国家临床实验室标准委员会建议的巯基乙酸培养液中获得的药敏结果进行了比较。目的是评估两种接种物制备方法中每种方法的重现性,并比较每种方法获得的MIC。对14种原种菌株进行了可重复性研究。通过直接琼脂法获得的模式MIC与参考肉汤法获得的模式MIC相同,分别为74%的时间和+/- 1 log2稀释范围内的100%的时间。两种方法中每种方法的重现度均相同(稀释度为93%+/- 1 log2)。通过直接琼脂法获得的MIC结果与通过参考肉汤培养法获得的MIC一致,在库存培养物的1,125个MIC数据对测定中占92.9%。在115个新鲜临床分离株的+/- 1 log2稀释步骤中,直接琼脂法的重现性为93%,其中脆弱类杆菌组的结果为93.4%。在这些临床分离株的708个MIC数据对中,仅发现了两个非常主要的差异(琼脂法错误易感)。直接从琼脂平板上生长制备接种物,为厌氧菌的琼脂稀释敏感性测试提供了一种快速且可重现的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号