Forty-one stock organisms and 581 fresh clinical isolates were used in comparing the Minitek system to conventional tubed media to determine if this system is feasible and accurate for a high-volume clinical microbiology laboratory. In addition to comparison with tubed media, the following parameters were tested: (i) reproducibility of disks, (ii) the effect of variation in inoculum size, (iii) the effect of the age of culture, and (iv) the effect of predispensing disks. A total of 5,947 disks were compared with tube reactions; 95.9% agreed on the initial reading. After repeating questionable tube and disk reactions, this agreement rose to 98.2%. Using the disk reactions and the identification schema currently in use with tubed media, 94.9% of the Minitek final identifications agreed with those of tubed media; 1.5% gave differing identifications and 3.6% were inconclusive. This system is accurate, inexpensive, flexible, and convenient.
机译:在将Minitek系统与常规试管培养基进行比较时,使用了41种原料生物和581种新鲜的临床分离株,以确定该系统对于大规模临床微生物学实验室是否可行和准确。除了与管式培养基进行比较外,还测试了以下参数:(i)圆盘的再现性,(ii)接种物大小变化的影响,(iii)培养年龄的影响,以及(iv)预分配磁盘。共比较了5947个圆盘与试管反应。 95.9%的受访者表示同意。在重复了可疑的管和盘反应之后,该协议上升到98.2%。通过使用盘式反应和目前用于管状介质的识别方案,Minitek 94.9%的最终识别结果与管状介质的一致。 1.5%给出了不同的标识,3.6%没有得出结论。该系统是准确,便宜,灵活和方便的。