In the three-phase four wire system of the low voltage side for the distribution grid, the phenomenon of asymmetrical and uneven single phase load were very common, causing unbalance in certain network. When unbalance exists, the system will have a larger line loss and the unbalanced loads can result in efficiency reduction of power energy and voltage quality decline. And then the safety and stabilization of power system in the low-voltage distribution grid will be directly affected. Therefore, based on the problems above, combined with the characteristic of the low voltage distribution grid in the three-phase four wire system, a three phase load unbalance automatic regulating system for low voltage distribution grid is designed. The system is composed of intelligent phase change controller and phase commutation switch. Based on the relevant theoretical analysis and experimental research applied in the system, the results show that this system can reasonably reduce load imbalance, improve power system performance, economic and social benefits.
机译:在配电网低压侧的三相四线制中,单相负载不对称不均匀的现象很普遍,导致某些电网不平衡。当存在不平衡时,系统将具有较大的线路损耗,并且不平衡的负载会导致电能效率降低和电压质量下降。进而直接影响低压配电网中电力系统的安全和稳定。因此,基于上述问题,结合三相四线制低压配电网的特点,设计了低压配电网的三相负荷不平衡自动调节系统。该系统由智能相变控制器和换相开关组成。通过对系统的相关理论分析和实验研究,结果表明,该系统可以合理减少负荷不平衡,提高电力系统的性能,经济效益和社会效益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号