摘要

The term “embedded generation”(EG) refers to electricity generation connected at distribution level rather than transmission level. E.G. can reduce the effect of losses while providing reactive power and contingency reserves to the network. It can also reduce the need for new transmission and distribution facilities consequently reducing overall costs. A distribution system is the system of an overall power system which links the bulk system to the individual customers. Voltage stability is an important performance index which defines the quality of supply. This paper presents the impact of embedded generation (EG) on power distribution system voltage collapse. ABUAD is considered as a case study in the research paper. The voltage stability indices (VSI) are calculated and assessed. The distribution network is reconfigured and the new values of VSI were computed to analyze the optimum configuration. The result of the paper showed that after thee reconfiguration of the system network the maximum KW, KVAR and KVA connected loads on the four selected transformers have increased by 9.11%, 9.04% and 8.44% respectively. The VSI for transformer T1 has increased from 0.0035 to 0.00362 while the VSI for transform T2 also decreased from 0.003845 to 0.0037 after the network reconfiguration. The VSI for transformer T3 and T4 remained constant even after the system network has been modified. The distribution system can be optimized for improved performance indices of which voltage stability is significant. Keywords: Embedded Generation, Voltages Collapse, Stability Index, Distribution Networks, Reconfiguration, Improved Performance, Transformers.
机译:术语“嵌入式发电”(EG)是指以配电级别而非输电级别连接的发电。例如。可以减少损耗的影响,同时为网络提供无功功率和应急储备。它还可以减少对新的传输和分配设施的需求,从而降低总体成本。配电系统是将整个系统链接到各个客户的整体电源系统。电压稳定性是决定电源质量的重要性能指标。本文介绍了嵌入式发电(EG)对配电系统电压崩溃的影响。 ABUAD在研究论文中被视为案例研究。计算并评估电压稳定性指数(VSI)。重新配置了配电网络,并计算了VSI的新值以分析最佳配置。论文的结果表明,在对系统网络进行重新配置后,所选的四个变压器上的最大KW,KVAR和KVA连接负载分别增加了9.11%,9.04%和8.44%。网络重新配置后,变压器T1的VSI从0.0035增加到0.00362,而变换T2的VSI也从0.003845减少到0.0037。即使修改了系统网络,变压器T3和T4的VSI仍保持恒定。可以优化配电系统,以提高电压稳定性显着的性能指标。关键字:嵌入式发电,电压崩溃,稳定性指标,配电网络,重新配置,提高性能,变压器。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号