Electrophysiological validation of total atrial conduction time measurement by tissue doppler echocardiography according to age and sex in healthy adults

机译:组织多普勒超声心动图根据年龄和性别对总心房传导时间进行测量的电生理学验证

获取原文
           

摘要

Background: We sought to validate total atrial conduction time (TACT) measurement via tissue Doppler imaging (TDI) by comparing the electrophysiological study (EPS) measurements of healthy subjects, according to age and sex. Methods: Eighty patients with normal EPS results were included. TACT was measured by EPS and TDI. For validation, the results of TDI were compared with those of EPS. TACT was assessed by measuring the time interval between the beginning of the P-wave on the surface ECG, and the peak A-wave on TDI from the left atrial lateral wall, just over the mitral annulus. Electrophysiological TACT was defined as the time from the high right atrial electrogram to the distal coronary sinus atrial electrogram around the left lateral portion of the mitral ring. Results: EPS and TDI measurements of the TACT were significantly and positively correlated among men and women in 20-30 years (p=0.008, r=0.412; p>0.001, r=0.706, respectively), and those in the 30-40 years group (p=0.001, r=0.649; p=0.001, r=0.696). In contrast, EPS and TDI measurements of TACT were not significantly different among men and women in the 20-30 years and those in the 30-40 years group (p>0.05, for both). On univariate regression analyses, TACT was independently associated with age (@b=0.342, =0.001). Conclusions: When assessed according to the age and sex of healthy participants, TDI and EPS measurements during TACT assessments were similar and correlated with each other. The measurement of TACT via TDI may be used accurately and confidently than the measurement via EPS in healthy individuals.
机译:背景:我们试图通过根据年龄和性别比较健康受试者的电生理研究(EPS)测量,通过组织多普勒成像(TDI)验证总心房传导时间(TACT)测量。方法:纳入80例EPS正常的患者。 TACT通过EPS和TDI进行测量。为了进行验证,将TDI的结果与EPS的结果进行了比较。通过测量表面ECG上的P波开始与正好位于二尖瓣环上方的左心房侧壁的TDI上的A波峰值之间的时间间隔来评估TACT。电生理学TACT定义为从高位右心房电图到二尖瓣环左外侧部分周围的远端冠状窦窦房电图的时间。结果:TACT的EPS和TDI测量值在20至30岁之间的男女之间呈显着正相关(分别为p = 0.008,r = 0.412,p> 0.001,r = 0.706)和在30-40岁之间年组(p = 0.001,r = 0.649; p = 0.001,r = 0.696)。相反,TACT的EPS和TDI测量值在20-30岁年龄组和30-40岁年龄组的男性和女性之间没有显着差异(两者均p> 0.05)。在单变量回归分析中,TACT与年龄独立相关(@ b = 0.342,= 0.001)。结论:根据健康受试者的年龄和性别进行评估时,TACT评估中的TDI和EPS测量值相似且相互关联。在健康个体中,与通过EPS进行的测量相比,通过TDI进行的TACT的测量可以准确,可靠地使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号