首页> 外文期刊>The Open Petroleum Engineering Journal >Heat Loss Test and Estimate for the Large-scale Floating Roof Tank
【24h】

Heat Loss Test and Estimate for the Large-scale Floating Roof Tank

机译:大型浮顶储罐的热损失测试与估算

获取原文
           

摘要

The heat loss and surface temperature of the top surface and sidewall of large-scale floating roof tank is testedby the heat flow meter and surface temperature method. Based on the test data, the heat loss from the top surface is abouttwice more than that of the sidewall which means the top surface is the weakest insulation part of the floating roof tank.On the surface, the heat loss profile is in accord with the surface temperature distribution. Special attention is given on thecalculation of thermal conductivity for the top surface and sidewall which finally deduced the total heat transfer coefficientof large floating roof tank. Moreover, the heat loss of floating roof tank in different working conditions is predicted.According to the calculation results, the level of 6m is regarded as a critical level determining the heat loss. And the centralizationstorage of oil is a more energy conservation storage pattern.
机译:采用热流量计和表面温度法对大型浮顶储罐顶部和侧壁的热损失和表面温度进行了测试。根据测试数据,顶表面的热损失比侧壁的热损失大两倍左右,这意味着顶表面是浮顶储罐最薄的隔热部分。表面温度分布。特别注意顶面和侧壁的导热系数的计算,最终得出大型浮顶罐的总传热系数。此外,还预测了浮顶储罐在不同工况下的热损失。根据计算结果,将6m的水平视为决定热损失的临界水平。石油的集中存储是一种更加节能的存储方式。